HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 Administrator Guide
NOTE:
• Depending on the environment, this issue might not be solved by setting the guide values. Make
sure that you adjust the values to suit your environment.
• In the following cases, set a value two to three times larger than the guide value.
When executing the HiScan command shortly after restarting the Device Manager agent.
When executing the hldutil command and HiScan command at the same time.
When executing multiple HiScan commands at the same time.
Related topics
• Changing Device Manager server properties, page 466
• server.http.entity.maxLength, page 469
• Changing Device Manager agent properties, page 529
• server.agent.maxMemorySize, page 537
• server.http.server.timeOut, page 545
• server.util.processTimeOut, page 545
Recommended property values to be set for a host that will manage 100 or more LUs (when
the host is not using a volume manager)
The following table lists the recommended property values for hosts that do not use a volume manager.
Table 92 Recommended property values for a host that will manage 100 or more LUs (when the host
is not using a volume manager)
server.util.
processTimeOut
(units: milliseconds)
server.http.
server.timeOut
(units: seconds)
server.http.
entity.maxLength
(units: bytes)
Number of LUs man-
aged by Device Man-
ager, and recognized
by the host
600,000
(Default value)
600
(Default value)
131,072 or more100
600,000600153,600 or more256
600,000600307,200 or more512
1,200,0001,200614,400 or more1,024
Related topics
• Changing Device Manager server properties, page 466
• server.http.entity.maxLength, page 469
• Changing Device Manager agent properties, page 529
• server.http.server.timeOut, page 545
• server.util.processTimeOut, page 545
Administrator Guide 355