HP XP P9000 Command View Advanced Edition Suite Software 7.6.0-00 Release Notes

Host Data Collector could not acquire host information for an AIX host that had a device whose
device file name was renamed by the rendev command.
If the hdc_target_getras command was executed on a system that was connected to an
HP-UX 11iv3 tape device, a problem, such as a tape access failure or data loss due to overwriting,
might have occurred.
If the TIC command was executed on a system that was connected to an HP-UX 11iv3 tape
device, a problem, such as a tape access failure or data loss due to overwriting, might have
occurred
Refreshing storage systems and copy pair operations did not finish if a command device in an
HP XP P9500 Storage device was recognized by a host with Device Manager Agent.
The user groups for external authentication groups could not be modified if they included certain
characters.
The value displayed for the number of logical volumes might be larger than the actual number of
logical volumes.
If LDEV IDs that made up a LUSE volume were added to or removed from a resource group, the
resource group might also have additional LDEV IDs added to or removed from it. These additional
LDEV IDs were unrelated to the target LUSE volume.
After upgrading Device Manager to V7.4.0 or later, the Device Manager generated a
KAIC00110-E error.
After an overwrite or upgrade installation of Device Manager installed in Linux, Element Manager
launch and acquisition of volume information did not succeed.
Important considerations
The Search dialog box, the Create Logical Group dialog box, and the Edit Logical
Group dialog box
When using the Search dialog box, the Create Logical Group dialog box, or the Edit Logical Group
dialog box, sometimes the filter conditions cannot be saved, and the following problems occur:
The KAIC03016-E message is displayed, and the search conditions in the Search dialog box
cannot be saved.
The KAIC15156-E message is displayed, and logical groups cannot be created in the Create
Logical Group dialog box.
The KAIC16993-E message is displayed, and logical groups in the Edit Logical Group dialog
box cannot be edited.
If an error occurs, shorten the character length of the filter condition.
If you want to save a filter condition that uses two-byte characters in the name, enter the two-byte
characters (no more than 16 characters) in the Edit Storage Systems dialog box or the
ModifyStorageArray command.
The ImportHosts command in the Device Manager CLI
If the total number of volumes visible from the WWN of all hosts is large
1
, and the ImportHosts
command is executed by specifying WWN from the Device Manager CLI, the Device Manager server
might run out of memory
2
. In this case, one of the following symptoms occurs:
Symptom 1:
The Device Manager server stops.
Symptom 2:
6 Important considerations