HP XP P9000 Command View Advanced Edition Software 7.6.
© Copyright 2013 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Version 7.6.0-00 Description This is the initial release of HP XP P9000 Command View Advanced Edition Software 7.6.0-00. For details, see “Enhancements ” (page 3). For previous behaviors resolved in this release, see “Fixes ” (page 5). For potential updates to these release notes, check the HP XP P9000 Command View Advanced Edition Software website: http://www.hp.com/support/cvae/manuals/ Update recommendation HP recommends updating to CVAE 7.6.0-00. Superseded version 7.5.
• The Device Manager CLI now supports the quiet option for commands, which suppresses command output.
• The Device Manager server, GUI, and CLI now support the virtualization server product VMware ESXi Server 5.1, Update 1. For details on guest operating systems, see HP XP P9000 Command View Advanced Edition Suite Software System Requirements. • For XP P9500 storage systems, Device Manager now supports 3.2 TB flash module drives. • The Device Manager GUI now supports Adobe Flash Player 11.8.
• Host Data Collector could not acquire host information for an AIX host that had a device whose device file name was renamed by the rendev command. • If the hdc_target_getras command was executed on a system that was connected to an HP-UX 11iv3 tape device, a problem, such as a tape access failure or data loss due to overwriting, might have occurred.
Volumes of hosts that are added by executing ImportHosts do not appear in the volume list in the GUI. 1 The total is number of volumes is considered to be large when the volumes visible from the WWN specified by the ImportHosts command exceeds 128,000. 2 If the Device Manager server runs out of memory, "java.lang.OutOfMemoryError: Java heap space" appears in the error.log3 file for Device Manager.
Installing Host Data Collector on a UNIX host Before installing Host Data Collector on a UNIX host, make sure that the host name of that UNIX host can be resolved correctly on that UNIX host. If the host name cannot be resolved correctly, a KAIG04047-E error is generated. KAIC17023-E error message in GUI If the GUI displays the KAIC17023-E error message, the storage system information might not have been refreshed, or the resource previously used for migration might not have been released.
In the hosts file, specify the IP address and host name of the host on which Host Data Collector is installed. Host Data Collector must be able to use this IP address to communicate with Device Manager server. Do not specify another IP address for that host. If a DNS server is used for name resolution, the host name must be resolvable to an IP address that Host Data Collector can use to communicate with Device Manager server. 2. Restart the service Host Data Collector Base Service.
When Device Manager server cannot start and a KAIC00114-E error message is generated If the Device Manager server cannot start and a KAIC00114-E error message is generated, even though another product installed on the same machine is not using a port used by the Device Manager server, restart the XP P9000 Command View Advanced Edition Suite product services. If this problem occurred during installation, the installation is interrupted, even if the installation was successful.
• ◦ 23051/tcp ◦ 23052/tcp Host Data Collector 7.5.
3. 4. Retrieve the allocated volume Confirm the allocated volume in the search results. JOB that unregisters Storage Logical Unit from the host when connected with SCVMM 2012 When executing the JOB that unregisters Storage Logical Unit from the host, the JOB generates error (2931). Cancel the allocated volume and manually update the information on SCVMM 2012 with the following procedure. 1. Log in to the object host to cancel the allocated volume. 2.
Importing the storage system labels to Device Manager When Refresh Labels (the operation to import the storage system labels to Device Manager) has over 20,000 volumes, do not the Refresh Labels at the same time as other tasks without considering the following factors: • • Confirm that there is no running task in Device Manager using one of the following methods: ◦ Display the Administration tab, then the Data Collection Tasks tab. ◦ Display the Task & Alerts tab.
Columns related to logical view: • IP Addresses Columns related to physical view: • WWN Columns related to system drives: • Host • WWN • Port • Host Group • LUN • Target ID • Copy Info (S-VOL) • Copy Info (P-VOL) • Parity Group • Volume Attributes Columns related to the Select THP Pool dialog box: • Volume Location • Drive Type • Drive Speed (RPM) • External LDEV Tier Rank Sorting and filtering columns The sort order of the following columns might not be correct.
• Drive Speed(RPM) • Total Capacity • Free Capacity • Usable Volumes • No. of Volumes THP pools columns: • Pool type • Subscription • No. of Parity Groups • Total Capacity Tiers columns: • Parity Group • Free Capacity • Tier No. • Volume Location • Drive Type • Drive Speed • No.
• Filesystem Used % • Vendor Parity groups columns: • Total Capacity THP pools columns: • Subscription Hosts columns: • OS Sorting volumes and pools The following columns might not be sorted properly in windows that contain lists of volumes: • Host • WWN In addition, the following columns might not be sorted properly in windows that contain lists of pools: • Drive Type • Drive Speed (RPM) AddLogicalUnit command in the Device Manager CLI When creating multiple LUs using the batch function in the
Device Manager GUI Element Manager Custom 25 Level30 Custom 26 Level31 Snapshot and Fast Snap search conditions or filter conditions When searching or filtering with Snapshot or Fast Snap, a symptom described in Symptom 1 or 2 below, occurs in one of the following dialog boxes: • Search dialog box • Create Tier dialog box • Migrate Data dialog box Symptom 1: If the specified search conditions or filter conditions meet either of the following conditions, pool volumes of the Snapshot pool and Fast
In this case, remove the host from the Device Manager server, and then restart the Device Manager server agent or deamon. The server.dispatcher.daemon.autoSynchro.logicalGroup.doRefresh property Even if true is specified for the server.dispatcher.daemon.autoSynchro.logicalGroup.doRefresh property in the dispatcher.properties file, information on logical groups is not updated automatically when any CLI commands are executed.
1. 2. 3. 4. Stop the Device Manager agent service and automatic execution of the HiScan command on the host. Check whether the target host is registered in any resource groups. Change the target host name. From the Device Manager GUI or CLI, change the host name to a completely different name. Example: Before: ABCD After: EFGH 5. 6. 7. 8. Start the Device Manager agent service and automatic execution of the HiScan command on the host.
In the GUI or the CLI, this issue occurs when all of the following conditions are met: • • Virtualize Volumes dialog box ◦ Capacity of selected volume from which the dialog box is launched is greater than 4,194,304 MB (4.0 TB), or a capacity that is greater than 4,194,304 MB (4.0 TB) is specified in the dialog box that is launched with selecting no volumes. ◦ An XP P9500 is selected for internal storage system. CLI AddExternalArrayGroup command ◦ XP P9500 is specified for the model parameter.
[FILE(2)] • Windows: \Server\config\server.properties • Linux: /Server/config/server.properties Property name: server.cim.http.port For https port number [FILE(1)] • Windows: \Server\wsi\server\jserver\bin\cimxmlscpa.properties • Linux: /Server/wsi/server/jserver/bin/cimxmlscpa.
Properties file location: • In Windows: installation-folder-for-the-Device-Manager-server\Server\config • In Linux: installation-directory-for-the-Device-Manager-server/Server/config Inaccurate error messages in the tier relocation starting operation for Smart pool when using manual mode If an error occurs in the tier relocation starting operation for a Smart pool when using manual mode, the following inaccurate error messages may be output.
Displaying the Unallocate Volume dialog box The volume capacity shown in the plan screen of the Unallocate Volume dialog box may be incorrect. If this occurs, see the task list to confirm the correct capacity.
Operations for logical groups in the GUI When many logical groups are displayed in the navigation area, if operations for a logical group are performed, the following message may appear. KAIC15901-E The session is not valid. You must log in again. (maintenance information=COMMUNICATION_ERROR) In the navigation area, extract the required logical groups for the operation.
CLI copy pair operation error 6119 A CLI copy pair operation may generate the error code 6119. If this occurs, check the following items. • Check the version of RAID Manager or RAID Manager XP that supports the required operation. • Check that RAID Manager or RAID Manager XP is properly installed. If this does not solve the problem, collect maintenance information and contact HP Technical Support.
The existing path group was not recommended for External Paths in the Virtualize Volumes dialog box and the volume virtualization was executed by using a new path group. Symptom 2 (GUI): The existing paths between storage systems were not displayed in order of External Path Priority in the Virtualize Volumes dialog box. Symptom 3 (GUI, CLI): The volume virtualization using the existing path group generated the following messages: • GUI: DevMgr 7.0.0-00 or later: KAIC06450-E • CLI: HDvM 6.1.
Launching XP P9500 Element Manager from Internet Explorer 7, 8, or 9 When Element Manager is launched from the Device Manager GUI, it is connected to the XP P9500 with HTTPS. If the following conditions are met, a certificate error occurs and Element Manager cannot be launched. 1. The browser used to display the Device Manager GUI is Internet Explorer 7, 8, or 9. 2. Common Name of the certificate is not the XP P9500 IP address.
Parity groups which can be searched using Keyword Search are in the following storage systems. • XP P9500 • XP24000/XP20000 • XP12000/XP10000/SVS200 Parity groups in storage systems other than the above cannot be searched using Keyword Search. Volume search: Search results might not be correct if is not is specified as a conditional equation in volume search by label. Only volumes assigned labels can be searched.
Enter the value of the tiering policy in the task name or description field when creating the editing tiering policy task. Removing Host Data Collector After removing Host Data Collector from a Solaris or Linux host, the following files or directories might remain. /Winexe /HostDataCollector/conf/HDCPid.dat Delete them manually after the removal. Host Data Collector can be reinstalled if these files or directories remain.
• Limits for each user ◦ • Number of user groups: 3 Limits for each resource group ◦ Number of LDEV IDs: 16,000 ◦ Number of host group numbers: 16,000 ◦ Parity groups: No limit ◦ Storage ports: No limit 2 If a user has 8 or more Device Manager client windows open at one time, the user might be forcibly logged out. Wait a few minutes, and then log in again.
3. Install Command View Advanced Edition. Specify a file system that can handle files larger than 2 GB for the installation destination of the Command View Advanced Edition database. For details about the installation procedure, see the HP XP P9000 Command View Advanced Edition Suite Software Installation and Configuration Guide. 4. Import the database. 1.
To add or remove resources, specify no more than 16,000 resources for each resource type. • When multiple resource groups are simultaneously deleted, communication with the Device Manager server might not succeed. Make sure that no more than 16,000 resources for each resource type are assigned to each resource group to be deleted. The number of resources assigned to a resource group can be confirmed in the resource group details window.
Filter values in the filter dialog box If a filter attribute is changed before its filter value in the filter dialog box is shown, the filter value might be inconsistent. If this occurs, redisplay the filters, or log in again. If the inconsistent filter value appears after refreshing the screen, set up a filter value again after applying a filter with a different attribute.
Warning banner preview The preview of the warning banner in the setting dialog box does not appear correctly. Confirm the warning banner in the login dialog box.
Operation not complete after logging in to GUI When the operation is not complete 30 minutes after logging in to the GUI, the following error might occur. The session is not valid. You must log in again. KAIC16009-E If this occurs, log in again. Task status in the Task Details dialog box If the Device Manager service stops while a task is executing, even if the status of the task changes to the Failure status, the Status column in the Task Details dialog box might display Waiting.
To confirm the number of paths in a logical group, view the logical group information without including the paths of the elements in the logical group, and then check the number of volume paths in the logical group. If above steps are not followed, and the number of logical groups and the number of volume paths in the logical groups becomes too large, a lot of memory will be used, which might cause the system response time to increase and errors to occur.
Using the GUI with Windows Server 2003 and Windows Server 2008 Because Internet Explorer on Windows Server 2003 and Windows Server 2008 enables Internet Explorer Enhanced Security Configuration (IE ESC) by default, you might experience the following situations: • Loading animation does not move. • You cannot download files from a server with HTTPS enabled. If this occurs, disable the Configure IE ESC.
Updating the display information of Plug-in for Virtualization Server Provisioning If an operation on the VMware ESX server or on a storage system is performed, the information provided by Plug-in for Virtualization Server Provisioning might not be updated. If the display information is not updated, log in to Plug-in for Virtualization Server Provisioning again.
Capacity information in the Plan Confirmation window of Plug-in for Virtualization Server Provisioning When a user executes an addstorage operation specifying a capacity that includes a value below the decimal point, the capacity information in the Plan Confirmation window might be different from the capacity specified by the user. However, the value entered by the user appears in VMware vSphere Client.
Changing the access port number of the HBase Storage Mgmt Web Service To change the access port number of the HBase Storage Mgmt Web Service, do not specify the following ports: 40 • 1(tcpmux) • 7(echo) • 9(discard) • 11(systat) • 13(daytime) • 15(netstat) • 17(qotd) • 19(chargen) • 20(FTP Data) • 21(FTP Control) • 22(ssh) • 23(telnet) • 25(smtp) • 37(time) • 42(name) • 43(nicname) • 53(domain) • 77(privrjs) • 79(finger) • 87(ttylink) • 95(supdup) • 101(hostriame
• 179(bgp) • 389(ldap) • 465(smtp+ssl) • 512(print / exec) • 513(login) • 514(shell) • 515(printer) • 526(tempo) • 530(courier) • 531(chat) • 532(netnews) • 540(uucp) • 556(remotefs) • 563(nntp+ssl) • 587(smtp) • 601(syslog) • 636(ldap+ssl) • 993(ldap+ssl) • 995(pop3+ssl) • 2049(nfs) • 4045(lockd) • 6000(x11) GUI operations after upgrading Device Manager After upgrading Device Manager, reboot the browser used as the GUI or clear a cache of the browser, and log int
Operating the Device Manager GUI Before completion of drawing a view, do not operate anything for it. If you do so, an unexpected error such as KAIC16009-E might occur. If this occurs, try the operation again. If this symptom continuously occurs, log in to the Device Manager again and retry the operation.
Allocate Smart Tiers Software volumes To allocate Smart Tiers Software volumes that have been allocated to hosts, perform either of the following operations: • Allocate volumes from the search result window • Allocate volumes from the logical group window KAIC15001-E error message in the GUI If the GUI displays the KAIC15001-E error message, startup of Device Manager might not have completed successfully.
• HiRDB/Developer's Kit • HiRDB/SQL Executer Adjusting the computer's time If a computer's time is changed while the services of Common Component and Command View Advanced Edition Suite products are running, Device Manager might not operate correctly. If you need to change the time, do so before installing.
Symbolic links (Linux) Ensure that the symbolic links indicated in the following table are not set. If any are set, installation might not be successful.
Installation instructions Manual references For installation information, see the following manual sections: Component Manual Device Manager server HP XP P9000 Command View Advanced Edition Suite Software Installation and Configuration Guide HP XP P9000 Command View Advanced Edition Suite Software Administrator Guide Device Manager GUI HP XP P9000 Command View Advanced Edition Suite Software User Guide Device Manager online help Device Manager CLI HP XP P9000 Command View Advanced Edition Suite Softw
Replication Manager Software 7.6.0-00 • HP XP P9000 Replication Manager Software Application Agent CLI Reference Guide (TB584-96079) Version 7.6.0-00 • HP XP P9000 Replication Manager Software Configuration Guide (TB584-96076) Version 7.6.0-00 • HP XP P9000 Replication Manager Software User Guide (TB584-96077) Version 7.6.0-00 • HP XP P9000 Replication Manager Software Application Agent CLI User Guide (TB584-96080) Version 7.6.