HP XP P9000 Command View Advanced Edition Suite Software 7.5.0-00 CLI Reference Guide (TB581-96348, July 2013)
Command specificationInformation to acquire
GetStorageArray subtarget=Path
pathsubinfo=WWN,HostInfo
Information about paths and WWNs for those paths
GetStorageArray subtarget=Pool
poolsubinfo=LogicalUnit
Information about pools and logical units for those pools
For details about parameters other than the parameter subtarget and the subinfo parameters, see
“GetStorageArray (subtarget not specified) ” on page 132 to “GetStorageArray
(subtarget=ReplicationInfo) ” on page 186.
GetStorageArray (subtarget not specified)
By executing GetStorageArray without specifying the subtarget parameter, you can obtain
basic information about all the storage systems (including SMI-S Enabled storage systems) that are
registered on the Device Manager server.
Format
When obtaining information about all storage systems:
hdvmcli [URL] GetStorageArray [options]
When obtaining information about a storage system (other than an SMI-S Enabled storage system):
hdvmcli [URL] GetStorageArray [options]
serialnum=serial-number model=model
When obtaining information about an SMI-S Enabled storage system:
hdvmcli [URL] GetStorageArray [options]
saobjid=object-ID-of-SMI-S-Enabled-storage-system
Parameters
Table 48 GetStorageArray (subtarget not specified) command parameters
DescriptionStatusParameter name
Serial number of the storage system
You cannot specify this parameter if you are obtaining information
about a particular SMI-S Enabled storage system.
Optional
#
serialnum
Model of the storage system
You cannot specify this parameter if you are obtaining information
about a particular SMI-S Enabled storage system.
Optional
#
model
Object ID of the SMI-S Enabled storage system
Specify the object ID obtained from another CLI response. The
value is encoded by the CLI.
Optional
#
saobjid
Command reference132