HP XP P9000 Command View Advanced Edition Suite Software 7.5.0-00 Administrator Guide (Web Version) (TB581-96346, July 2013)
#1:
If the host is a virtual machine and you execute the hldutil command after changing the con-
figuration of the P-VOL or S-VOL, this information might not be displayed correctly. In this case,
restart the virtualization server to display the information correctly.
#2:
In the case of HP-UX 11i v3, this item is not displayed for a persistent special device (persistent
device special file).
#3:
If the virtual WWN is assigned to the virtual machine by using NPIV, the physical WWN of the
virtualization server is displayed.
The following table lists the correspondence between the string output for RaidID and the storage
system model.
Table 104 Correspondence between RaidID and storage system models
ModelRaidID
XP1024
R450
XP128
R451
XP12000
R500
XP10000
R501
SVS 200
R502
XP24000
R600
XP20000
R601
P9500
R700
javapath_setup command
The javapath_setup command is used to switch the Java execution environment used on the Device
Manager agent when the host OS is Windows or Linux. The javapath_setup command is stored
in the following location:
In Windows:
installation-folder-for-Device-Manager-agent\bin\javapath_setup.exe
In Linux:
/opt/HDVM/HBaseAgent/bin/javapath_setup.sh
The following table describes the javapath_setup command syntax.
Table 105 javapath_setup command syntax
DetailsItem
javapath_setup {-set [new|bundle|Java-execution-environment-install-
ation-path]|-check}
Synopsis
Using and maintaining the Device Manager agent266