HP StorageWorks XP Replication Monitor software installation and configuration guide (T1784-96008, November 2006)
Maintaining and tuning the system 97
Table 6-10 Parameters of the agent.properties file
Parameter Setting details
agent.rm.TimeOut
1
Time limit for a response from the RAID Manager XP command used by the XP
Replication Monitor agent (in seconds)
A value between 0 and 86400 can be set. 0 means no time-out.
agent.rm.everytimeShutdown
1
Setting for whether to stop the HORCM instance for monitoring
2
every time
Specify true or false. If true is specified, the instance stops every time.
If false is specified, the instance does not stop
agent.rm.shutdownWait Wait time when stopping the HORCM instance for monitoring
2
(in seconds)
A value between 1 and 60 can be set.
agent.rm.horcmInstance Instance number of the HORCM file for monitoring
2
A value between 0 and 4094 can be set. This value must be different from
the instance number of the configuration definition file of another RAID
Manager XP.
agent.rm.horcmService UDP port number of the HORCM file for monitoring
2
A value between 0 and 65535 can be set. This value must be different from
the port number of another application.
agent.rm.horcmSource Location (directory) of the configuration definition file of the existing RAID
Manager XP
Use ASCII characters to specify a file location (directory).
agent.logger.loglevel Log file output level for the XP Replication Monitor agent
Logs that have levels equal to or higher than the value specified here are
output. The following values (listed in ascending order of importance) can be
specified:
DEBUG, INFO, WARN, ERROR, FATAL
agent.logger.MaxBackupIndex Number of generations of log files for the XP Replication Monitor agent
Maximum number of log files to be generated. When the number of log files
generated reaches this value, the log files are reused, beginning with the
oldest one. A value between 1 and 20 can be set.
agent.logger.MaxFileSize Size of log files for the XP Replication Monitor agent
Maximum size of each log file. A value between 512 KB and 32 MB can be
set. You can specify the value in bytes, kilobytes, or megabytes. If no unit is
specified for the number, it is assumed to be in bytes.
1
Normally, the values set for these parameters do not need to be changed. To change their values, you need
expert knowledge of the XP Replication Monitor agent.
2
The HORCM instance for monitoring means an instance of RAID Manager XP used by the XP Replication
Monitor agent. The HORCM file for monitoring means the configuration definition file of that RAID Manager XP.