HP StorageWorks XP Replication Monitor software installation and configuration guide (T1784-96008, November 2006)

Installing XP Replication Monitor software 40
Following an uninstallation progress message, a message reporting that uninstallation has finished is
displayed, and then the installer is terminated.
3. From the property file, delete unneeded parameters.
Of the parameters that were added to the property file server.properties during the installation,
delete those items that are not used by other agents, such as the Device Manager agent.
2-5 Importing the alert settings for the earlier version
When performing an upgrade installation of the XP Replication Monitor server, during the installation procedure,
you can specify whether to continue using the alert settings for the earlier version. If you specify that you continue
using the settings, the settings will be exported. In this case, after the upgrade installation completes normally,
you need to import the settings to the XP Replication Monitor server.
To import the alert settings, use the hrpmdbconvert command. In a Windows system, only a member of the
Administrators group can execute this command.
The format, and storage destination directory for the file that contains the alert settings, which is created in the
export processing during the installation, are as follows:
File format: CSV
File storage destination directory:
installation-directory-for-Replication-Monitor\tmp\HRpMAlertSettingData
The format and installation directory for the hrpmdbconvert command are as follows:
Command format:
hrpmdbconvert.bat /datapath name-of-the-directory-storing-the-alert-settings-
files
Use the absolute path when specifying the file name in the datapath parameter.
Command installation directory:
Replication-Monitor-server-installation-directory\bin
To import the alert settings for the earlier version:
1. Acquire the most recent configuration information
From the management client, log in to XP Replication Monitor software to acquire copy pair configuration
information. For details on how to acquire the configuration information, see section
3-7 .
2. Stop the Common Component services and the Device Manager service.
In the management server, stop the Common Component services (HBase Storage Mgmt Web Service and
HBase Storage Mgmt Common Service) and the Device Manager service.
3. Execute the hrpmdbconvert command to import the alert settings.
In the management server, execute the hrpmdbconvert command.
In a cluster configuration, perform this step on the executing node.
4. Restart the Common Component services and the Device Manager service.
In the management server, restart the Common Component services (HBase Storage Mgmt Web Service
and HBase Storage Mgmt Common Service) and the Device Manager service.
2-6 After finishing the installation
2-6-1 Notes on uninstalling Device Manager
Do not uninstall Device Manager in an environment where XP Replication Monitor software is installed. When
uninstalling the Device Manager, first uninstall XP Replication Monitor software.
If the Device Manager is uninstalled in an environment where XP Replication Monitor software is installed, even if
the Device Manager is reinstalled, XP Replication Monitor software cannot be used. To use XP Replication