HP StorageWorks XP Command View Advanced Edition Software 6.4 Server Administrator Guide for Device Manager and Provisioning Manager (web) (T1780-96341, July 2010)

Table Of Contents
Overview
34
1-4-4 System requirements for XP512/XP48
The following table describes the prerequisite firmware versions and software products.
Table 1-18 Prerequisite firmware versions and software products for XP512/XP48
Prerequisite firmware versions Prerequisite software products
SVP microcode : 01-19-99-00/02 or later HP SNMP API
XP LUN Manager
To set up security for LUNs:
XP Virtual LVI/LUN (VLL) and Volume
Shredder
To use functions for creating a LUSE or LDEV
(CVS):
HP StorageWorks XP LUN Expansion
To use the copy pair functionality:
HP StorageWorks XP Business Copy
Software
HP StorageWorks XP Continuous Access
Synchronous Software
HP StorageWorks XP Continuous Access
Asynchronous Software
If you set up an alias for HPAV, the LDEV number assigned for both the base volume and the
alias volume must be in the same 32-LDEV boundary (for example, 0 to 31, 32 to 63). If the
LDEV boundary is not the same, you may see the following error message when you try to
create an LDEV:
The volume to be created by the CVS operation is being used as the MAV
function.
For more information about HPAV, see Hitachi Parallel Access Volume (HPAV) User and
Reference Guide.
If you use XP Continuous Access Software or XP Business Copy Software, see section 1-7 for
the requirements.
For more information on installing and configuring other software, see XP Remote Web
Console Error Codes for the XP512/XP48.
NOTE: Do not use DHCP if you use Device Manager to manage the storage subsystem.
1-4-5 System requirements for other storage subsystems
XP Tiered Storage Manager can use storage subsystems managed by an SMI-S provider (hereafter
referred to as SMI-S Enabled subsystems) as external subsystems.
To use SMI-S Enabled subsystems as external subsystems, you need to add the SMI-S Enabled
subsystems by using Device Manager and, depending on the operating environment, you need to
specify security settings for port numbers and communication.
Also, after creating a system, you need to use Device Manager web client or CLI to manage the
SMI-S Enabled subsystems.