HP StorageWorks P9000 Tiered Storage Manager Software 7.1 CLI Reference Guide (TB585-96011, May 2011)
totalCapacityInGB=8,552
usedCapacityInGB=1,616
usedCapacityPercentage=45
freeCapacityInGB=1,976
freeCapacityPercentage=55
numberOfStorageTiers=25
numberOfMigrationGroups=13
refreshStatus=Success
An instance of StorageDomain(2 of 2)
name=MegaTechXP12000-Secondary
totalCapacityInGB=Unknown
usedCapacityInGB=Unknown
usedCapacityPercentage=Unknown
freeCapacityInGB=Unknown
freeCapacityPercentage=Unknown
numberOfStorageTiers=3
numberOfMigrationGroups=3
refreshStatus=Failure
List of 1 ErrorInfo elements:
An instance of ErrorInfo(1 of 1)
message=KATS62010-E message-contents
• Command execution example (3):
In this example, summary information is obtained for the storage domain MegaTechXP12000-
Primary that needs to be refreshed.
htsmcli GetStorageDomains name="MegaTechXP12000-Primary"
• Execution results (3):
RESPONSE:
List of 1 StorageDomain elements:
An instance of StorageDomain(1 of 1)
name=MegaTechXP12000-Primary
totalCapacityInGB=8,552
usedCapacityInGB=6,576
usedCapacityPercentage=77
freeCapacityInGB=1,975
freeCapacityPercentage=23
numberOfStorageTiers=0
numberOfMigrationGroups=0
refreshStatus=RefreshRequired
KATS10622-W message-contents
ModifyStorageDomain
The ModifyStorageDomain command can be used to change information (the name or description)
for a storage domain.
Note that information cannot be changed for storage domains in the following states:
• Storage domains that contain tasks that have not ended (End)
CLI Reference Guide 61