HP StorageWorks P9000 Tiered Storage Manager Software 7.1 CLI Reference Guide (TB585-96011, May 2011)
# emulationType=OPEN-V
# CVS=Yes
# capacityInKB=10,240,320
# LBA=20,480,640
# subsystem=XP24000@172.16.110.1
# SLPRNumber=0
# CLPRNumber=0
# arrayGroupName=1-6-1
# diskType=-
# RAIDLevel=RAID5(3D+1P)
# cacheMode=Unknown
# IOSuppressionMode=Unknown
# xpThinProvisioning=-
# arrayGroupBusyRate=
# arrayGroupMaxBusyRate=
# targetControllerDeviceNumber=00:0A:09 * (00:0A:00)
# targetControllerDeviceNumber=00:0A:0C * (00:0A:02)
# targetControllerDeviceNumber=00:0A:12
# targetControllerDeviceNumber=00:0A:1E
# Target candidates for source LDEV - 00:0A:00, 00:0A:02
# emulationType=OPEN-V
# CVS=Yes
# capacityInKB=10,486,080
# LBA=20,972,160
# subsystem=XP24000@172.16.110.1
# SLPRNumber=0
# CLPRNumber=0
# arrayGroupName=1-4-1
# diskType=-
# RAIDLevel=RAID5(3D+1P)
# cacheMode=Unknown
# IOSuppressionMode=Unknown
# xpThinProvisioning=-
# arrayGroupBusyRate=
# arrayGroupMaxBusyRate=
# targetControllerDeviceNumber=00:07:F3
# targetControllerDeviceNumber=00:07:F4
# targetControllerDeviceNumber=00:07:F5
# targetControllerDeviceNumber=00:07:F6
# targetControllerDeviceNumber=00:07:F9
• Command execution example (3):
This example uses the same conditions as those used for Command execution example (1) to
create a candidate migration plan, except that the capacities of some migration target volumes
are larger than those of their migration source volumes.
htsmcli CreateMigrationPlan storagedomainname="MegaTechXP12000-Primary"
migrationgroupname="MG011" targetstoragetiername="MegaTech-HighCost"
• Execution results (3):
#Example plan for migration
Details of CLI commands112