HP StorageWorks P9000 Command View Advanced Edition Suite Software System Requirements (7.1.0-00) (TB581-96054, May 2011)
Management server requirements
8
Table 1-4 Required Disk Space (Linux)
Item Default Installation Directory Required Disk Space
Installation directory for the setup
support utility
/opt/CVXPAE/Utility
Installation directory for the Host
Data Collector
/opt/CVXPAE/HostDataCollec
tor
/opt/CVXPAE/Winexe
Storage directory of the database
for Common Component
1
/var/opt/CVXPAE/database
750 MB
/var/opt/CVXPAE/Base/datab
ase/Base
Storage directory of the database
for the Device Manager server
/var/opt/CVXPAE/database/D
eviceManager
700 MB
Storage directory of the database
for the Tiered Storage Manager
server
/var/opt/CVXPAE/database/H
TSM
150 MB
Storage directory of the database
for the Replication Manager server
/var/opt/CVXPAE/database/H
RpM
250 MB
Installation directory for the
common library
1
/opt/hitachi
1 MB
Output directory for common trace
log files
12
/var/opt/hitachi/HNTRLib2/
spool
1 MB
Output directory for installation
log files
/opt/CVXPAE/HInst
10 MB
A temporary directory
3
/var/tmp
1.7 GB
NOTE: Note that the /opt/CVXPAE portion can be changed. Read it as the directory specified during
installation.
1
This is not required if a HP StorageWorks P9000 Command View Advanced Edition Suite product
has already been installed.
2
You can change the size and number of generations of common trace log files.
3
This is required only during installation, and is unnecessary after installation.
1-2 Software requirements
Installation of the HP StorageWorks P9000 Command View Advanced Edition Suite requires a
computer that satisfies the following software requirements.
1-2-1 Prerequisite OS
Table 1-5 to Table 1-6 describe the prerequisite OSs for the HP StorageWorks P9000 Command
View Advanced Edition Suite.
Table 1-5 Usable management server OSs (Windows)
OS Edition Service pack HP StorageWorks P9000
Command View Advanced
Edition Suite
IPv6