HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 CLI Reference Guide (TB581-96066, September 2011)
ArrayGroup instance
The ArrayGroup instance is output when the following commands are executed:
• “AddExternalArrayGroup” on page 41
• “AddPool” on page 64
• “AddVirtualVolume” on page 76
• “GetStorageArray (subtarget=ArrayGroup) ” on page 111
• “GetStorageArray (subtarget=FreeSpace) ” on page 122
• “GetStorageArray (subtarget=PDEV) ” on page 147
• “GetStorageArray (subtarget=Pool) ” on page 149
• “ModifyPool” on page 171
Table 106 ArrayGroup instance attributes
DescriptionAttribute
Object ID of the parity group
objectID
Parity group name
This item is output if it has been registered.
name
Number of the chassis containing the parity group
chassis
Parity group number
number
Display name of the parity group (example: 1, 1-1, 2-1-1, S3-1)
S in the above format indicates the type of the parity group.
• E: Parity group of an External volume
• V: Parity group of V-VOL
• X: Parity group of a volume for Thin Provisioning Software
displayName
RAID level of the parity group
RAID levels are output in the format RAIDx(yD+zP).
• RAIDx: RAID level
• yD: Number of data drives
• zP: Number of parity drives
For example, RAID5(3D+1P) indicates a RAID5 configuration consisting of three
data drives and one parity drive.
raidType
Emulation mode
This item is output for the XP24000/XP20000, XP12000/XP10000/SVS200, or
XP1024/XP128 (example: OPEN-8).
emulation
Type of physical drives that make up the parity group (example: DKR2E-J146FC)diskType
Size (in GB units for type tag) of physical drives that make up the parity group
(example: 72)
0 is output for an external volume.
diskSize
Output items284