HP P9000 Tiered Storage Manager Software 7.4.1-00 Release Notes (TB585-96030, March 2013)
• The Tiered Storage Manager server, GUI, and CLI now support Red Hat Enterprise Linux 6.3.
• The Tiered Storage Manager GUI now supports Firefox ESR 17.0.x for Linux.
• For P9500, the Tiered Storage Manager now supports zero page reclaim of THP volumes that
have Business Copy configurations.
Fixes
Fixes for 7.4.1-00
The following issues have been resolved:
• A task for data migration registered from Tiered Storage Manager terminated abnormally with
the KAIC08101-E, KAIC08104-E, KAIC08106-E, or KATS62010-E error.
• If you used the CLI to set the tier management of Smart pools to auto, and then used the GUI to
execute a THP-pool-editing task, the task generated the KAIC08140-E error.
Important considerations
Specifying is not or <> in filter conditions
When is not or <> is specified in a filter condition for one of the following columns in a window
that lists parity groups, volumes, or Data Placement Profiles, data that does not meet the filter conditions
may be displayed.
Columns related to parity groups:
• Parity Group
• Drive Type
• Drive Speed (RPM)
Columns related to volumes:
• Host
• Target ID
• Copy Info (S-VOL)
• Copy Info (P-VOL)
• Parity Group
• Volume Attributes
Columns related to Data Placement Profiles:
• Status
Executing the GetFreeSpaces command for an SMI-S Enabled storage system
After changing the name of an SMI-S Enabled storage system from the Device Manager GUI, if the
GetFreeSpaces command of the Tiered Storage Manager CLI was executed with the
SubsystemName property specified for the filtercondition parameter, filtering was not correctly
performed and the results output by the command were empty.
If you want to execute the GetFreeSpaces command for an SMI-S Enabled storage system whose
storage name was changed from the Device Manager GUI, change the storage name by using the
ModifyStorageArray command of the Device Manager CLI.
4 Fixes