HP P9000 Command View Advanced Edition Suite Software 7.4.1-03 Release Notes (TB581-96357, May 2013)

On a virtualization server, the following operations did not succeed; additionally, the following
operations and conditions generated the incorrect error message KAIC05512-E:
Creating a virtual machine
Configuring a virtual machine
Registering the virtualization server with Device Manager
Refreshing information on the virtualization server using Device Manager or Host Data
Collector on Device Manager for Windows
The virtualization server did not have a bootable virtual machine
If the JDK used by Host Data Collector was set to Oracle JDK 6 or later, the Host Data Collector
Base Service did not start.
If you have a remote copy pair managed by a Business Continuity Manager instance that was
registered as an information source in Replication Manager, and you used Replication Manager
to reverse the copy direction of the copy pair, and then to split the remote copy pair, when you
executed a restore operation, the Device Manager storage view might not display the pair
information..
Values displayed in the following were larger than the actual values for a volume logical group
that included a LUSE volume:
In the [Resources] tab
[Total Capacity] under [Summary]
In the [Mobility] tab dashboard:
[Total Capacity] under [Summary]
[Used Capacity: Basic] under [Summary]
[Basic Total] under [Drive Type Summary]
[Basic] under [Drive Type Distribution]
The following situations occurred if you specified an XP P9500 storage port in a command and
then executed that command from the Device Manager CLI:
If you specified CLB-M (port number: 117) for the name of a storage system port and then
executed a command that changed the configuration or acquired information, the configuration
was changed or information was acquired for the port CLD-M (port number: 118).
If you specified CLD-M (port number: 118) for the name of a storage system port and then
executed a command that changed the configuration or acquired information, the configuration
was changed or information was acquired for the port CLB-M (port number: 117).
The following symptoms occurred in the list of host volumes:
Operation A: You displayed the list of volumes.
Symptom A: LUSE volume information incorrectly appeared as follows:
The displayed number of No. of Paths was more than the actual number.
Information about a non-representative LDEV that made up the LUSE volume sometimes
appeared.
Hyphens (-) sometimes appeared when they should not.
Fixes 7