HP P9000 Command View Advanced Edition Suite Software 7.4.1-03 Release Notes (TB581-96357, May 2013)

Launching Element Manager by using a 32-bit browser in a 64-bit Windows environment
To launch Element Manager on a storage system other than XP P9500 by using a 32-bit browser in
a 64-bit Windows environment, install 32-bit Java plug-in, and then set the value in the storage system
manually to 32-bit Java plug-in.
If an error message such as an out-of-memory error is displayed and Element Manager cannot be
launched, check the settings of the 32-bit java plug-in.
This applies to the following storage systems:
XP12000/XP10000/SVS200
XP1024/XP128
Reschedule Tasks
If tasks for which the start time passed are selected from the task list in the Tasks & Alerts tab and
Reschedule Tasks is executed, Reschedule Tasks does not complete successfully and generates the
following incorrect message:
KAIC63504-E Unable to execute task. (task name = "<task name>"
Note that the rescheduling tasks for which the start time passed is not supported in Reschedule Tasks.
Changing the IP address of a host added by a Device Manager agent
When the Device Manager agent is installed, and either the IP address of the host was changed or
the server.http.socket.agent Address property in the server.properties file for the host
was changed, the IP address was not reflected for the Device Manager Server, even though the Device
Manager agent service or deamon was restarted.
In this case, remove the host from the Device Manager server, and then restart the Device Manager
server agent or deamon.
The server.dispatcher.daemon.autoSynchro.logicalGroup.doRefresh
property
Even if true is specified to the
server.dispatcher.daemon.autoSynchro.logicalGroup.doRefresh property in the
dispatcher.properties file, information on logical groups is not updated automatically when
any CLI commands are executed.
Smart Tiers for Mainframe
If Device Manager is managing XP P9500, Smart Tiers for Mainframe pools are displayed as Thin
Provisioning for Mainframe pools.
As a result, all attributes specific to Smart Tiers for Mainframe (for example, tier information) cannot
be viewed in Device Manager. Use Element Manager to view the attributes specific to Smart Tiers for
Mainframe.
Unallocating volumes and deleting storage for Plug-in for Virtualization Server
Provisioning by selecting hosts in the GUI
In the Unallocate Volumes dialog box or the Delete Storage dialog box, the KAIC15457-E error
message appears, tasks cannot be created, and WWN is removed from a host group when all of the
following conditions are met:
Several WWNs belonging to hosts are assigned to a host group.
The host group in the first condition has 257 or more LUNs.
In the hosts in the first condition, you open the Unallocate Volumes dialog box or the Delete Storage
dialog box by selecting some of the hosts.
Important considerations 17