HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 CLI Reference Guide (TB581-96335, April 2013)
• GetStorageArray (subtarget=FreeSpace) , page 145
Table 128 FreeSpace instance attributes
DescriptionAttribute
Object ID of a region of unused capacity in the parity group
objectID
Size of a region of unused capacity in the parity group (in KB)
sizeInKB
Number of cylinders in a region of unused capacity in the parity group
0 is output for open volumes.
cylinders
Index number of a region of unused capacity in the parity group
Indexes are automatically reassigned whenever regions of unused capacity are
affected by the creation and deletion of LDEVs.
fsControlIndex
Host instance
The Host instance is output when the following commands are executed:
• AddHost, page 260
• AddHostRefresh, page 263
• AddVirtualizationServer, page 265
• GetHost, page 272
• MergeHost, page 288
• ModifyHost, page 290
• ModifyVirtualizationServer, page 295
• RefreshVirtualizationServer, page 298
Table 129 Host instance attributes
DescriptionAttribute
Object ID of the host
objectID
Host name
If EXSP_xxxx_xxxx_xxxx is output as this value, the value indicates an
XP12000/XP10000/SVS200 port connected to an external storage system.
name
ID of the host
hostID
IPv4 IP address of the host
ipAddress
IPv6 IP address of the host
ipv6Address
Size of the LDEV allocated to the host (in KB)
For mainframe hosts, the value output for this attribute is 0.
capacityInKB
Output items352