HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 Administrator Guide (TB581-96334, April 2013)
server.agent.rm.ignorePairStatus
Specify whether to omit copy pair information when sending host information from the Device Manager
agent to the management server.
Specify true to omit copy pair information. Specify false if you do not want to omit the information.
In the following environments, make sure that you always specify true:
• Virtual machine for which a copy pair is assigned
• An SVP is used as a virtual command device to manage copy pairs defined as a device group.
When P-VOLs and S-VOLs are assigned to the management server, this property must be specified.
Default: false
server.agent.rm.horcmSource
If the RAID Manager configuration definition file is stored in a location other than the default, use the
absolute path to specify the storage location of the configuration definition file.
Specify the path according the following rules:
• In Windows, use a forward slash (/) as a path delimiter.
• In Windows, if a space is included in the path, you do not need to enclose the path with quotation
marks (").
• Do not use symbolic links.
Default: None
#
#: If you do not specify a path, the path for the following default storage location is used:
In Windows:
System folder (represented by the environment variable %windir%)
In UNIX:
/etc directory
Related topics:
• Changing the storage location of the configuration definition file, page 251
Administrator Guide (Web Version) 423