HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 Administrator Guide (TB581-96334, April 2013)
Default: 3
Related topics:
• server.cim.http.port, page 355
• server.cim.https.port, page 355
server.cim.http.port
Specify the port for non- SSL transmission for the CIM function.
Default: 5988
Related topics:
• server.cim.support.protocol, page 354
server.cim.https.port
Specify the port for SSL transmission, for the CIM function.
Default: 5989
Related topics:
• server.cim.support.protocol, page 354
server.configchange.enabled
Specify whether to automatically update (refresh) storage system information in the database when
the storage system configuration is changed by a storage management tool (Element Manager)
launched from the GUI.
If you specify true for this property, the database is automatically refreshed immediately after the
configuration change. If you specify false, it is not automatically refreshed.
Default: true
server.logicalview.initialsynchro
Specify whether to forcibly synchronize the storage system information in the database with the
information displayed in the GUI or CIM/WBEM functions when Device Manager server is started.
If you specify true, the information will be synchronized. If you specify false, the information will
not be synchronized.
Default: false
server.mail.enabled
Specify whether to send alerts and events to users by email.
To enable this email notification function, set this property to true. To disable this function, set this
property to false.
Default: true
Administrator Guide (Web Version) 355