HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 Administrator Guide (TB581-96334, April 2013)
DescriptionParameter name
Time at which the Device Manager server acquired alert information
Display format: yyyy/mm/dd hh:mm:ss
hh is displayed by using 24-hour display.
occurrenceTime
2. Restart the P9000 Command View AE Suite product services.
Related topics:
• Starting services, page 197
• Stopping services, page 198
Sending SNMP traps to log files
Device Manager receives SNMP traps issued by devices on the network and outputs them to log files.
SNMP traps (SNMP version1 only) issued by devices that are not management targets can also be
output to log files, as well as SNMP traps issued by the management-target storage systems.
Received SNMP traps are output to the following files:
• Event log or syslog
• P9000 Command View AE Suite shared trace log files (hntr2n.log)
• Device Manager trace log files (HDvMtracen.log)
• Trace log files (trace.log)
•
Error log files (error.log)
#
#:
Output only if the severity level is Error, Critical, or Alert. The severity levels for SNMP
traps are specified for the customizedsnmptrap.customizelist property in the cus-
tomizedsnmptrap.properties file.
The following SNMP trap information is output:
• Message ID indicating that a trap was received (prefix: KAID)
• Sender (agent)
• Enterprise ID (enterprise)
• Generic trap number (generic)
• Specific trap number (specific)
If integrated management software is linked with, you can centrally monitor the operational status of
all network resources, including the storage resources managed by Device Manager.
Related topics:
• Setting up Device Manager to output SNMP traps, page 143
• Changing Device Manager server properties, page 350
• customizedsnmptrap.customizelist, page 371
Setting up logs and alerts142