HP P9000 Command View Advanced Edition Suite Software 7.4.0-00 CLI Reference Guide (TB581-96326, December 2012)
Table Of Contents
- CLI Reference Guide
- Table of Contents
- Preface
- 1 Overview
- 2 Environment settings
- 3 Executing commands
- 4 Command reference
- Storage system commands
- AddArrayReservation
- AddExternalArrayGroup
- AddHostStorageDomain
- AddLabel
- AddLogicalUnit
- AddLUSE
- AddPool
- AddStorageArray
- AddTieredPoolOperation
- AddVirtualVolume
- DeleteArrayReservation
- DeleteExternalArrayGroup
- DeleteHostStorageDomain
- DeleteLabel
- DeleteLogicalUnit
- DeleteLUSE
- DeletePool
- DeleteStorageArray
- DeleteVirtualVolume
- FormatLU
- GetArrayReservation
- GetPoolShrinkStatus
- GetStorageArray
- Using the GetStorageArray parameter
- GetStorageArray (subtarget not specified)
- GetStorageArray (subtarget=ArrayGroup)
- GetStorageArray (subtarget=CommParameters)
- GetStorageArray (subtarget=Component)
- GetStorageArray (subtarget=ExternalStorage)
- GetStorageArray (subtarget=Filter)
- GetStorageArray (subtarget=FreeSpace)
- GetStorageArray (subtarget=HostStorageDomain)
- GetStorageArray (subtarget=LDEV)
- GetStorageArray (subtarget=LogicalDKC)
- GetStorageArray (subtarget=LogicalUnit)
- GetStorageArray (subtarget=MFReplicationInfo)
- GetStorageArray (subtarget=Path)
- GetStorageArray (subtarget=PDEV)
- GetStorageArray (subtarget=Pool)
- GetStorageArray (subtarget=Port)
- GetStorageArray (subtarget=PortController)
- GetStorageArray (subtarget=ReplicationInfo)
- GetStorageArray (subtarget=TieringPolicy)
- GetTieredPoolStatus
- GetZeroPageReclaimStatus
- ModifyArrayReservation
- ModifyExternalTierRank
- ModifyLabel
- ModifyLogicalUnit
- ModifyPool
- ModifyPort
- ModifyPortController
- ModifyStorageArray
- ModifyTieringPolicy
- ModifyVirtualVolume
- RefreshPerformanceData
- RefreshStorageArrays
- RunZeroPageReclaim
- ShrinkPool
- Logical group commands
- LUN commands
- Host management commands
- Server management commands
- Replication commands
- Storage system commands
- 5 Output items
- Alert instance
- ArrayGroup instance
- ArrayReservation instance
- CommParameters instance
- Component instance
- ConfigFile instance
- Datastore instance
- ExternalPathInfo instance
- ExternalStorage instance
- FreeLUN instance
- FreeSpace instance
- Host instance
- HostInfo instance
- HostStorageDomain instance
- IPAddress instance
- LDEV instance
- LogicalDKC instance
- LogicalGroup instance
- LogicalUnit instance
- MFReplicationInfo instance
- ObjectLabel instance
- PairedPool instance
- PairedPortController instance
- Path instance
- PDEV instance
- PerformanceStatus instance
- Pool instance
- PoolTier instance
- Port instance
- PortController instance
- RelatedDistributedArrayGroup instance
- ReplicationControllerPair instance
- ReplicationGroup instance
- ReplicationInfo instance
- ServerInfo instance
- StorageArray instance
- TieringPolicy instance
- URLLink instance
- VirtualDisk instance
- VM instance
- VolumeConnection instance
- WWN instance
- 6 Batch functionality
- 7 Import functionality
- 8 Properties file
- Overview of the properties file
- Using the properties file to specify options
- Using the properties file to specify parameters
- Setting up the execution environment
- Specifying the log file
- Specifying a log level
- Message trace output
- Specifying the URL
- Inputting requests from XML documents
- Using the message trace file
- Output format of execution results
- Outputting execution results in CSV format
- Outputting execution results in XML format
- Specifying a DTD
- Using a DTD with the Device Manager CLI
- 9 Troubleshooting
- 10 Support and other resources
- A Connecting to P9000 mainframe agent
- About connecting to P9000 mainframe agent
- Setting up the mainframe host environment
- Setting up the Device Manager environment
- Refreshing information recognized by the mainframe host
- Acquiring P9000 mainframe agent information registered in Device Manager
- Changing P9000 mainframe agent information registered in Device Manager
- Deleting P9000 mainframe agent information registered in Device Manager
- Acquiring mainframe host information
- Changing mainframe host information
- Deleting a mainframe host
- Glossary
- Index
For P9500, you need to specify at least one of the following parameters: threshold,
threshold2, threshold2mode, overprovisioningwarning, overprovisioninglimit,
adddevnums, tiercontrol, automigration, migrationinterval, monitorstarttime,
monitorendtime, or monitoringmode.
#2
For XP24000/XP20000, you need to specify at least one of the following parameters: threshold,
overprovisioningwarning, overprovisioninglimit, or adddevnums.
#3
If you specify threshold values for overprovisioningwarning and overprovisioninglim-
it, two levels of warnings related to the over-provisioning percent can be issued. For
XP24000/XP20000, these threshold values are specific to and managed by the Device Manager
server.
#4
The over-provisioning percent is the percentage of the total size of all THP/Smart volumes with
respect to the THP/Smart pool size. For example, if the THP pool size is 500 GB and the total
size of all THP volumes is 400 GB, the threshold value will be 80 %.
#5
For details about the values used when tiercontrol or automigration setting is changed
from disable to enable, and migrationinterval, monitorstarttime, monitorend-
time, and monitoringmode are omitted, see “AddPool” on page 72.
#6
There must be an interval of at least one hour between the times specified for monitorstarttime
and monitorendtime. The same time cannot be specified for monitorstarttime and
monitorendtime.
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
poolid
Obtain this value from the execution result of the GetStorageArray (subtarget=Pool)
command. In the execution result of this command, the poolID value appears under An in-
stance of Pool. Use this value to specify the poolid parameter.
adddevnums
Obtain this value from the execution result of the GetStorageArray (subtarget=Logic-
alUnit, lusubinfo=LDEV) command. Execute this command by specifying only the model
and serialnum parameters, LogicalUnit for the subtarget parameter, and LDEV for the
lusubinfo parameter. In the execution result of this command, the devNum value of LogicalUnit
appears under An instance of LogicalUnit. Use the devNum value of a logical unit that
satisfies the conditions to be used as a pool volume in a THP/Smart pool, to specify the ad-
ddevnums parameter.
Command execution example
In this example, the ModifyPool command expands the Smart pool whose pool ID is 5 (poolid: 5)
in the storage system (serialnum: 53039, model: P9500).
Command reference198