HP P9000 Command View Advanced Edition Suite Software 7.4.0-00 CLI Reference Guide (TB581-96326, December 2012)
Table Of Contents
- CLI Reference Guide
- Table of Contents
- Preface
- 1 Overview
- 2 Environment settings
- 3 Executing commands
- 4 Command reference
- Storage system commands
- AddArrayReservation
- AddExternalArrayGroup
- AddHostStorageDomain
- AddLabel
- AddLogicalUnit
- AddLUSE
- AddPool
- AddStorageArray
- AddTieredPoolOperation
- AddVirtualVolume
- DeleteArrayReservation
- DeleteExternalArrayGroup
- DeleteHostStorageDomain
- DeleteLabel
- DeleteLogicalUnit
- DeleteLUSE
- DeletePool
- DeleteStorageArray
- DeleteVirtualVolume
- FormatLU
- GetArrayReservation
- GetPoolShrinkStatus
- GetStorageArray
- Using the GetStorageArray parameter
- GetStorageArray (subtarget not specified)
- GetStorageArray (subtarget=ArrayGroup)
- GetStorageArray (subtarget=CommParameters)
- GetStorageArray (subtarget=Component)
- GetStorageArray (subtarget=ExternalStorage)
- GetStorageArray (subtarget=Filter)
- GetStorageArray (subtarget=FreeSpace)
- GetStorageArray (subtarget=HostStorageDomain)
- GetStorageArray (subtarget=LDEV)
- GetStorageArray (subtarget=LogicalDKC)
- GetStorageArray (subtarget=LogicalUnit)
- GetStorageArray (subtarget=MFReplicationInfo)
- GetStorageArray (subtarget=Path)
- GetStorageArray (subtarget=PDEV)
- GetStorageArray (subtarget=Pool)
- GetStorageArray (subtarget=Port)
- GetStorageArray (subtarget=PortController)
- GetStorageArray (subtarget=ReplicationInfo)
- GetStorageArray (subtarget=TieringPolicy)
- GetTieredPoolStatus
- GetZeroPageReclaimStatus
- ModifyArrayReservation
- ModifyExternalTierRank
- ModifyLabel
- ModifyLogicalUnit
- ModifyPool
- ModifyPort
- ModifyPortController
- ModifyStorageArray
- ModifyTieringPolicy
- ModifyVirtualVolume
- RefreshPerformanceData
- RefreshStorageArrays
- RunZeroPageReclaim
- ShrinkPool
- Logical group commands
- LUN commands
- Host management commands
- Server management commands
- Replication commands
- Storage system commands
- 5 Output items
- Alert instance
- ArrayGroup instance
- ArrayReservation instance
- CommParameters instance
- Component instance
- ConfigFile instance
- Datastore instance
- ExternalPathInfo instance
- ExternalStorage instance
- FreeLUN instance
- FreeSpace instance
- Host instance
- HostInfo instance
- HostStorageDomain instance
- IPAddress instance
- LDEV instance
- LogicalDKC instance
- LogicalGroup instance
- LogicalUnit instance
- MFReplicationInfo instance
- ObjectLabel instance
- PairedPool instance
- PairedPortController instance
- Path instance
- PDEV instance
- PerformanceStatus instance
- Pool instance
- PoolTier instance
- Port instance
- PortController instance
- RelatedDistributedArrayGroup instance
- ReplicationControllerPair instance
- ReplicationGroup instance
- ReplicationInfo instance
- ServerInfo instance
- StorageArray instance
- TieringPolicy instance
- URLLink instance
- VirtualDisk instance
- VM instance
- VolumeConnection instance
- WWN instance
- 6 Batch functionality
- 7 Import functionality
- 8 Properties file
- Overview of the properties file
- Using the properties file to specify options
- Using the properties file to specify parameters
- Setting up the execution environment
- Specifying the log file
- Specifying a log level
- Message trace output
- Specifying the URL
- Inputting requests from XML documents
- Using the message trace file
- Output format of execution results
- Outputting execution results in CSV format
- Outputting execution results in XML format
- Specifying a DTD
- Using a DTD with the Device Manager CLI
- 9 Troubleshooting
- 10 Support and other resources
- A Connecting to P9000 mainframe agent
- About connecting to P9000 mainframe agent
- Setting up the mainframe host environment
- Setting up the Device Manager environment
- Refreshing information recognized by the mainframe host
- Acquiring P9000 mainframe agent information registered in Device Manager
- Changing P9000 mainframe agent information registered in Device Manager
- Deleting P9000 mainframe agent information registered in Device Manager
- Acquiring mainframe host information
- Changing mainframe host information
- Deleting a mainframe host
- Glossary
- Index

snapshotVolumeType=Simplex
journalVolumeType=Simplex
sysVolFlag=0
externalVolume=0
differentialManagement=false
SnapshotPoolID=-1
journalPoolID=-1
thpType=-1
consumedCapacityInKB=-1
thpPoolID=-1
threshold=-1
tcaPoolID=-1
thpPoolVolControlFlag=-1
managementAreaPoolID=-1
*****: The value is encoded by the CLI.
ModifyPool
ModifyPool expands a THP/Smart pool or changes the settings related to the THP/Smart pool.
NOTE:
• This command can be used only with P9500 and XP24000/XP20000.
• The attributes of the Pool instance, thresholdVolForewarn and thresholdVolOverwarn,
which were output as the execution results of this command, have changed to overProvision-
ingWarning and overProvisioningLimit, respectively. Check and, if necessary, revise
the script settings that you use in version 6.3 or later.
To expand a THP/Smart pool, the following conditions must be satisfied:
• The conditions on logical units to be specified as pool volumes, which are listed in “Ad-
dPool” on page 72.
• For P9500 and XP24000/XP20000, the status of the THP/Smart pool is not Blocked and the
usage rate is not 100%.
For P9500 and XP24000/XP20000, the following conditions must be satisfied if you want to change
the settings related to a THP/Smart pool:
• If the status of the THP/Smart pool is Normal, the usage rate is less than 95%.
• When changing the threshold value, you specify a value that is larger than the value set for the
usage rate of the THP/Smart pool at that time.
Format for P9500
When the command is used to expand a THP/Smart pool:
hdvmcli [URL] ModifyPool [options]
model=model serialnum=serial-number poolid=pool-ID
adddevnums=device-number-of-logical-unit
[threshold=THP/Smart-pool-threshold-1]
[threshold2=THP/Smart-pool-threshold-2] [threshold2mode={0|1}]
[overprovisioningwarning=over-provisioning-warning-threshold]
[overprovisioninglimit=over-provisioning-limit-threshold]
[tiercontrol={enable|disable}]
CLI Reference Guide 193