HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 Administrator Guide (web)

Table Of Contents
When the system uses the central management method, specify this value to manage all copy
pairs with a single host (pair management server). To use the central management method, you
must install the Device Manager agent and RAID Manager only in the pair management server,
and the Device Manager agent only in other hosts.
When the central management method is used, if the pair management server recognizes the
command device in each storage system, the server can use all LUs, including LUs that are not
recognized by the hosts of each storage system, to create copy pairs.
Default: disable
server.agent.rm.cuLdevForm
Specify the output format for LDEV numbers when pair volume information is written in HORCM_LDEV
format in the configuration definition file when creating pairs. If omitted, the information will be output
in decimal format.
DECIMAL
Specify to output in decimal format.
CULDEV
Specify to output in CU:LDEV format.
HEXA
Specify to output in hexadecimal format.
This property is enabled only when creating copy pairs for P9500, XP24000/XP20000,
XP12000/XP10000/SVS200, or XP1024/XP128. In addition, if a virtual command device is used
for the target copy pair command device (if a command device is set for the HORCM_CMD parameter
in IPCMD format), LDEV numbers will be output in decimal format regardless of the value specified
for this parameter.
Default value: CULDEV
server.agent.rm.exclusion.instance
On the host where the Device Manager agent is installed, to exclude volume pairs already managed
by RAID Manager from Device Manager operations, specify the applicable RAID Manager instance
numbers. The volume pairs excluded from Device Manager operations are also excluded from
Replication Manager operations. To specify multiple instance numbers, separate the individual numbers
with commas (,). From the Device Manager agent, you cannot operate a RAID Manager whose
instance number is specified in this property.
Default: None
server.agent.rm.location
Specify the RAID Manager installation directory in the following cases:
RAID Manager is installed in a location other than the default location
The host OS is Windows, and the RAID Manager installation drive is different from the Device
Manager agent installation drive
For Windows, you cannot specify \ as a delimiter. Use \\ or / instead.
Default for Windows: drive-where-Device-Manager-agent-is-installed/HORCM
Default for UNIX: /HORCM
Administrator Guide (Web Version) 403