HP P9000 Command View Advanced Edition Suite Software 7.2 Administrator Guide (web)

Message descriptionsOutput levelType of message
An error occurred, but execution can continue with limitations.20
Warning
Information has been produced about the actions of the management
server and management client.
0
Information
Information has been produced about exchanges with other programs
or machines.
10
Information has been produced about the starting/stopping of a
major method, or the creation/deletion of a major object.
20
Detailed information has been produced.30
CAUTION:
If you have changed the property value, restart the services of P9000 Command View AE Suite
products to enable the new value.
logger.syslogLevel
This setting specifies a threshold output level for event log data and syslog data output by Tiered
Storage Manager. Messages with an output level equal to or lower than the one specified in this
property will be written to an event log or syslog.
Any value from 0 to 30 can be specified. We recommend that the default value be used.
Default: 0
CAUTION:
If you have changed the property value, restart the services of P9000 Command View AE Suite
products to enable the new value.
logger.serverMessageFileCount
Specify the number of message log files used by the Tiered Storage Manager server. The range of
specifiable values is from 2 to 16.
When a log file reaches the maximum size specified in the logger.serverMessageMaxFileSize
property, the file is renamed by adding a counter to the file name (for example,
HTSMServerMessage2.log). The log files are used and written to in the order of the counter. A
round robin method is applied, meaning that after the end of the last file has been reached, the first
file is overwritten.
After the Tiered Storage Manager server starts, writing continues to the file to which the last log data
was written, regardless of whether the server stopped normally last time.
Default: 10
Administrator Guide (Web Version) 347