HP P9000 Command View Advanced Edition Software Update 7.1.0-02 Release Notes (TB581-96077, August 2011)

This issue occurs when all of the following conditions are met:
No Replication Manager license is registered, and Replication Manager is started from Device
Manager.
From the Pair Configurations view (accessible by ExplorerResourcesPair Configurations, the
Copy Pair Summary is viewed (accessible by selecting Pair ConfigurationsPair Management
ServersConfig FilesCopy Groups.
Copy pairs that cannot be viewed are in the copy group selected in the previous issue.
KAIC6003-E error occurs during shrink pool function
An unexpected error (KAIC60003-E) might appear without the message when using shrink pool.
If this occurs, confirm if the task of shrink pool has completed in Element Manager. If the shrink pool
task has completed in Element Manager, execute the format task.
Refresh the storage system by using the P9000 Command View Advanced Edition Software after the
format task completes.
KAIC16993-E error occurs during create pool function
The error message Failed:AsynchronousProcessCounter#decrement (KAIC16993-E)
might appear when one of the following operations is continuously performed in the Create Pool dialog
box.
Addition of tiers
Deletion of tiers
Addition of parity groups
Deletion of parity groups
If this occurs, close the Create Pool dialog box, and then retry the operation.
Registering a Solaris 10 host by using Host Data Collector
A zpool_history_<zfs pool name>-<1 to 6digit number>.rst file with a file size
of 0 bytes is created in the /tmp directory on the Solaris 10 host when you:
Register a host, or update host information.
Have a ZFS pool name that is longer than 98 bytes.
When you run the target host log gathering tool (TLC), the file zpool_history_<zfs pool
name>-<1 to 6digit number>.rst and the file <any character>-<1 to 6digit
number>.rst (size: about 250 + 50*disk number that consists pool byte) might be created in the
same directory where you ran the TLC tool.
Delete these files from the directory after registering hosts, updating host information, or running TLC.
Search window
An unexpected error (KAIC16009-E) might occur when the Search button is clicked immediately after
displaying the Search window. If this occurs, close the error dialog box, and then retry the search.
Search window filters
If a filter attribute value is changed before initialization is complete, the value may become invalid or
operations from the window may not be able to be performed. If this occurs, redisplay the filters or
log in again.
Important considerations 11