HP StorageWorks Command View SDM Installation and User Guide (T1086-96023, February 2005)

52 Installing Command View SDM
Enabling EMS Monitoring
If EMS monitoring is running on an HP-UX host when Command View SDM is
installed, the array(s) will be automatically configured into the event
monitoring. In this situation the following steps do not need to be performed.
It will be necessary to manually enable EMS if Command View SDM has been
installed in the following environments:
Command View SDM is installed on a Windows or Linux host that will
be communicating with an HP-UX host running EMS.
Command View SDM is installed on an HP-UX host that is not running
EMS, but will be communicating with an HP-UX host that is running
EMS.
EMS monitoring is installed on an HP-UX host after
Command View SDM has been installed.
To manually enable EMS, perform the following steps:
1 On an HP-UX host which is running EMS, perform the following steps. On
all other hosts, go to step 2.
a Open the following file in a text editor:
/var/stm/config/tools/monitor/RemoteMonitor.cfg
b Edit the entry for DISK_ARRAY to read as follows:
DISK_ARRAY ENABLE
c Save the file.
d Continue with step 2.
2 Open the following file in a text editor:
/opt/sanmgr/commandview/server/config/PanConfigParams.txt
3 Edit the following entry to read as follows:
EMS_HOST=hostname
hostname is the name of the host running EMS
4 Save the file.
Setting the System Display Variable
When launching the GUI under HP-UX or Linux, the system environmental
variable DISPLAY must be set to the system you are logged on to. In most