HP StorageWorks Command View SDM Installation and User Guide (T1086-96023, February 2005)

Command Line User Interface 125
Command Line User Interface
need not be a single discharge cycle from 100% to 0%. It could be two cycles
of 100% to 50%, four cycles of 100% to 75%, etc. The key factor is that the
entire capacity of the battery has been discharged and recharged for each
count.
The battery initiates a reconditioning cycle when necessary. This causes the
battery to go through a full discharge/recharge cycle. Each reconditioning
cycle adds to the total Discharge Cycles count.
Displaying FRU Information
Display the FRU information for array with alias
jupiter.
armdsp -f jupiter
Vendor ID:______________________________HP
Product ID:_____________________________A6218A
Array World Wide Name:__________________50060b00000921d2
Array Serial Number:____________________00SG04990111
Alias:__________________________________jupiter
Software Revision:______________________1.08.00 - 0126 - 040630
Command execution timestamp:____________Jul 2, 2004 9:27:17 PM
------------------------------------------------------------
FRU HW COMPONENT IDENTIFICATION ID STATUS
===========================================================================
M Enclosure 00SG04990111 Downed
M/P1 Power Supply 82004EK00347 Good
M/P2 Power Supply 82004EK00322 Good
M/MP1 MidPlane 000484710092 Good
M/C2 Controller 00PR00033908 Good
M/C2.H1 Host Port <none> Good
M/C2.H2 Host Port <none> Good
M/C2.J1 BackEnd Port <none> Good
M/C2.J2 BackEnd Port <none> Good
M/C2.B1 Battery 28903:MOLTECHPS:NI2040:2002/3/25 Good
M/C2.PM1 Processor HP:A6218A:A120 Good
M/C2.M1 DIMM 1024 Good
M/C1 Controller 00PR00003395 Good
M/C1.H1 Host Port <none> Good
M/C1.H2 Host Port <none> Good
M/C1.J1 BackEnd Port <none> Good
M/C1.J2 BackEnd Port <none> Good
M/C1.B1 Battery 28726:MOLTECHPS:NI2040:2002/3/19 Good
M/C1.PM1 Processor HP:A6218A:A120 Good