HP StorageWorks Command View SDM Installation and User Guide (T1086-96023, February 2005)
124 Command Line User Interface
Status:_____________________________Good
Port Instance:______________________1
Hard Address:_______________________126
Link State:_________________________Link Down
Node WWN:___________________________50060b00000970bc
Port WWN:___________________________50060b000014a134
Back Port At M/C2.J1:
Status:_____________________________Good
Port Instance:______________________0
Hard Address:_______________________125
Link State:_________________________Link Up
Node WWN:___________________________50060b00000970bc
Port WWN:___________________________50060b000014a133
Topology:___________________________Private Loop
Data Rate:__________________________2 GBit/sec
Port ID:____________________________125
Back Port At M/C2.J2:
Status:_____________________________Good
Port Instance:______________________1
Hard Address:_______________________126
Link State:_________________________Link Down
Node WWN:___________________________50060b00000970bc
Port WWN:___________________________50060b000014a135
Battery at M/C2.B1:
Status:_____________________________Good
Identification:_____________________28771:MOLTECHPS:NI2040:2002/3/19
Manufacturer Name:__________________MOLTECHPS
Device Name:________________________NI2040
Manufacturer Date:__________________March 19, 2002
Remaining Capacity:_________________5657 mAh
Remaining Capacity:_________________94 %
Voltage:____________________________12655 mVolts
Discharge Cycles:___________________6
Processor at M/C2.PM1:
Status:_____________________________Good
Identification:_____________________HP:A6218A:A120
DIMM at M/C2.M1:
Status:_____________________________Good
Identification:_____________________1024
Capacity:___________________________1024 MB
More About Battery Discharge Cycles
The battery Discharge Cycles value represents the total number of times a
complete discharge/recharge cycle of the battery capacity has occurred. This