HP StorageWorks Command View SDM Installation and User Guide (T1086-96023, February 2005)
Command Line User Interface 115
Command Line User Interface
About Firmware Files
The following information should be used when downloading firmware files.
■ Firmware files for the HP StorageWorks Virtual Array products are
available at the following locations on the HP Support web:
http://www.hp.com/support/va7100
http://www.hp.com/support/va7400
■ When downloading firmware files, it is recommended that they be put in
the following folders:
...\sanmgr\commandview\client\fwdownload for arrays
...\sanmgr\commandview\client\sbin for JBOD.
This is the default location. If the files are placed in another location, the path
must be specified.
■ There are two types of firmware files, raw (.LOD) and wrapped (.FRM).
Wrapped files contain header information that allow the download utilities
to verify that the firmware file matches the hardware component. Use only
wrapped files when downloading firmware.
New Firmware Revision Code Designation for VA 7410
The revision numbering for firmware has changed for the VA 7410. The
revision numbering consists of a string of 4 ASCII characters (the HP
designation has gone away). For example, a revision code of "X123"
represents the following:
— X - Is a single capital letter (A - Z) designating the platform
— 1 - is a single number or capital letter (0-9, A-Z) designating a major
FW revision
— 2 - is a single number or capital letter (0-9, A-Z) designating a minor
FW revision
— 3 - is a single number or capital letter (0-9, A-Z) designating a sub-
minor FW revision
The initial firmware release for the VA 7410 is A000.