HP QLogic Converged Network Adapter Installation Guide (747713-001, September 2013)
• Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.
Wrist straps are flexible straps with a minimum of 1 megohm (±10 percent) resistance in the
ground cords. To provide proper ground, wear the strap snug against the skin.
• Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both
feet when standing on conductive floors or dissipating floor mats.
• Use conductive field service tools.
• Use a portable field service kit with a folding static-dissipating work mat.
In absence of any of the suggested equipment for proper grounding, have an HP-authorized reseller
install the part.
NOTE: For more information on static electricity, or assistance with product installation, contact
your HP-authorized reseller.
HP Restricted Grounding methods 15