HP XP Cluster Extension Software 6.01.00 Release Notes for Windows (5697-2450, July 2013)
Enhancements
This release includes the following enhancements:
• Support for Cluster Shared Volumes [CSV] on Windows Server 2012 Failover Cluster only.
• Support for Failover cluster integrated CLX resource configuration utility for Cluster Shared
Volume on Windows Server 2012 only
• In CLX configured environments, support for automatic management of virtual machine
migrations residing on Cluster Shared Volume in Windows Server 2012 Failover Cluster only
• Support for Automatic creation of CLX cluster resources in CSV Role and VM Role using
PowerShell Cmdlets on Windows Server 2012 only.
• Support for HP XP Cluster Extension solution for HP XP Continuous Access 3DC environment.
NOTE: For more information, see HP XP Cluster Extension Disaster Recovery solution for XP
CA 3DC multi-target with Delta resync configuration whitepaper at www.hp.com/storage/
whitepapers or https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?
productNumber=CLX .
Prerequisites
• Windows Server 2008 only: In certain situations, resources do not follow the Preferred Owners
List order during failover. See the Microsoft Knowledge Base article KB950181 for more
information.
• A physical disk resource may unexpectedly fail or go offline when the IsAlive function is run
on a Windows Server 2008 cluster node. See the Microsoft Knowledge Base article KB953652
for more information.
• Immediately after installing HP XP Cluster Extension, bringing a resource online might fail with
the error Create process to execute command "horcmstart instance" failed.
This error occurs because the RAID Manager environment path variable value is not reflected
for the HP XP Cluster Extension resource. If you experience this problem, restart the cluster
service on the affected cluster node. After you restart the cluster service, this error message
will not appear again.
• After installing CLX, the RAID manager related path environment variable value does not get
updated to CLX in the Server Core and Hyper-V server environments. To workaround this issue,
either re-login to the Windows session of the cluster nodes or reboot the cluster nodes.
• To enable use of the HP OpenView AutoPass GUI, install the Java Runtime Environment (Java
SE Release families 1.6.0 or later) and set the path environment variable for java.exe.
Installation instructions
For installation instructions, see the following manual:
Manual name: HP XP Cluster Extension Software Installation Guide
Part number: 5697-2449
Publishing year: June 2013
Compatibility/Interoperability
For applicable versions and other compatibility details, see the HP SPOCK website: http://
www.hp.com/storage/spock.