HP P6000 Cluster Extension Software Administrator Guide (5697-0986, June 2011)

HP SMI-S parameters. clxresconf verifies the P6000 Cluster Extension
resources of your MS cluster or the defined applications (APPLICATION tag)
in the UCF.cfg. File output shows the resource name/application tag name
and the status of the configuration.
Syntax clxresconf [-mscs|-ucf]
Operands Must be specified to check all P6000 Cluster Extension
resources in the MSCS cluster.
–mscs
–ucf If you use the clxevarun CLI integration and created a
UCF.cfg file, you can verify the file using this option.
Example
C:\>cd %HPCLX_EVA_PATH%\bin
C:\Program Files\Hewlett-Packard\Cluster Extension
EVA\bin>clxresconf -mscs
Application Name...... Status
-------------------------------------------------------------
my-exchange.....Configuration OK
clx-sql1........Error: Can not get management host's
username/password.
Please check it with PMU tool.
clx-iis1........Error: Connection to SMA Failed.
clx-share.......Error: Only find passive SMA.
clx-test........Error: SMI-S exception.
C:\Program Files\Hewlett-Packard\Cluster Extension EVA\bin>
clxpmu
Description clxpmu is a menu-driven console application used to manage P6000 Cluster
Extension SMI-S server/management server login information on each cluster
node. This information is needed for P6000 Cluster Extension to communicate
with the management server. clxpmu saves the information to the
clxsmiscfg file. The clxsmiscfg file is encrypted and its contents can
only be viewed with clxpmu.
Syntax clxpmu
Return codes
0
OK
CAUTION:
The changes made using the P6000 Cluster Extension password management utility (clxpmu) are
only saved on the local node on which it is run. To make the changes global, you must manually run
clxpmu on each node or copy the file clxsmiscfg to each node in the cluster after you save the
changes in clxpmu. In Linux, clxsmiscfg is located in /opt/hpclxeva/bin. HP recommends
that you create a backup copy of the clxsmiscfg file before running clxpmu.