HP P6000 Cluster Extension Software Administrator Guide (5697-0986, June 2011)
6005-08b4-0010-2971-0000-8000-00e9-0000"
---- Sample clxobjectpaths.cfg end
Copy the consistency set object path from clxobjpaths.cfg to the P6000
Cluster Extension configuration file.
---- Sample P6000 Cluster Extension configuration file begin
APPLICATION CLXWEB
DC_A_Hosts Host1 Host2
DC_B_Hosts Host3 Host4
DeviceGroup \Data Replication\DRG142
DC_A_StorageCellWWN 50001FE100270C30
DC_B_StorageCellWWN 50001FE100270CA0
DC_A_ManagementHosts CLXSMAXLXLA
DC_B_ManagementHosts CLXSMAXLXLB
CSObjectPathA HPEVA_ConsistencySet.InstanceID="50001FE100270C30.
6005-08b4-0010-2e9b-0000-5000-0025-0000"
CSObjectPathB HPEVA_ConsistencySet.InstanceID="50001FE100270CA0.
6005-08b4-0010-2971-0000-8000-00e9-0000"
---- Sample P6000 Cluster Extension configuration file end
Return codes clxconf exits with one of the following return codes:
OK: clxconf successfully obtained both consistency set object paths for all of
the applications.
0
FAILURE: clxconf failed to obtain both consistency set object paths for one
or more of the applications.
3
clxgetobjpath
Description clxgetobjpath uses the clxsmiscfg file to access the HP SMI-S server
to retrieve the CSObjectPath values from both P6000/EVA storage systems,
printing the values to standard out.
Syntax clxgetobjpath SMA_hostname [DC_A_EVA_WWN DC_B_EVA_WWN
DR_Group]
Operands Management server host nameSMA_hostname
DC_A_EVA_WWN WWN of the P6000/EVA array in data center A
DC_B_EVA_WWN WWN of the P6000/EVA array in data center B
DR_Group The DR group name
If you only provide the management server host name, it will test the connec-
tion to this host. There will be no output if the return code is OK.
If you provide the P6000/EVA array WWNs and a DR group name, the
output will show the SMI-S CSObjectPath(s) values.
CLI commands and utilities94