HP P6000 Cluster Extension Software Administrator Guide (5697-0986, June 2011)
DC_A_ManagementHosts smam019fk351k # active sma
DC_B_ManagementHosts clxeva1 # passive sma
FailsafeMode disable
DC_A_Hosts w2k7 w2k6
DC_B_Hosts w2k5 w2k8
CSObjectPathA HPEVA_ConsistencySet.InstanceID="50001FE15002B5A0.
6005-08b4-
0001-4cf1-0000-6000-061f-0000"
CSObjectPathB HPEVA_ConsistencySet.InstanceID="50001FE15002B570.
6005-08b4-
0001-6e12-0000-7000-031a-0000"
---- Sample UCF.cfg end
Example 2
RHCS or SLE HA integration configuration
# clxconf -smis -sg /etc/opt/hpclxeva/conf/CLXEVA.config
CLXWEB
In this example, clxconf assumes that you have created a P6000 Cluster
Extension configuration file with the minimum information needed to obtain
the consistency set object paths.
• DC_A_StorageCellWWN
• DC_B_StorageCellWWN
• DC_A_ManagementHosts
• DC_B_ManagementHosts
• DeviceGroup
These items are needed to map the DR group to the P6000 Cluster Extension
resource. The following content is from a sample P6000 Cluster Extension
configuration file:
NOTE:
The APPLICATION name value must match the RHCS service
name and the App name of a P6000 Cluster Extension resource
configured using SLE HA.
---- Sample P6000 Cluster Extension configuration file begin
APPLICATION CLXWEB
DC_A_Hosts Host1 Host2
DC_B_Hosts Host3 Host4
DeviceGroup \Data Replication\DRG142
DC_A_StorageCellWWN 50001FE100270C30
DC_B_StorageCellWWN 50001FE100270CA0
DC_A_ManagementHosts CLXSMAXLXLA
DC_B_ManagementHosts CLXSMAXLXLB
---- Sample P6000 Cluster Extension configuration file end
clxconf will get the consistency set object paths and place them in
clxobjpaths.cfg (located in the P6000 Cluster Extension directory /
etc/opt/hpclxeva/conf).
---- Sample clxobjectpaths.cfg begin
APPLICATION CLXWEB
CSObjectPathA HPEVA_ConsistencySet.InstanceID="50001FE100270C30.
6005-08b4-0010-2e9b-0000-5000-0025-0000"
CSObjectPathB HPEVA_ConsistencySet.InstanceID="50001FE100270CA0.
HP P6000 Cluster Extension Software Administrator Guide 93