HP P6000 Cluster Extension Software Administrator Guide (5697-0986, June 2011)
hpclxeva/conf/CLXEVA.config). To obtain the value of this object, run the
clxconf utility (see “clxconf” on page 91).
CLI-specific behavior
You must enter this object in the user configuration file (UCF.cfg) when you use
P6000 Cluster Extension's CLI. To obtain the value of this object, run the clxconf
utility (see “clxconf” on page 91).
DataSyncTimeout
Format Integer
Description Specifies the timeout value for a DR group member synchronization when the source
and destination remote copy sets are not synchronized. The timeout value is used
if the ApplicationStartup object is set to RESYNCWAIT.
Default value 170 seconds
DC_A_Hosts (Required)
Format List
Description This space-separated list defines the cluster nodes in data center A.
DC_B_Hosts (Required)
Format List
Description This space-separated list defines the cluster nodes in data center B.
DC_A_ManagementHosts (Required)
Format List
Description Space-separated list of management servers for data center A. P6000 Cluster Ex-
tension attempts to establish a management path (HP SMI-S) connection with one
of the management servers on the hosts in the list. The first host in the list that estab-
lishes a successful connection with P6000 Cluster Extension is used as the manage-
ment path for the failover operation. P6000 Cluster Extension attempts to connect
to the management hosts in the local data center first, before using management
hosts in the remote data center. The hosts listed for data center A are associated
with data center A and do not necessarily need to be physically located in data
center A. You can specify the hosts using either the system host name or the IP
address.
DC_B_ManagementHosts (Required)
Format List
HP P6000 Cluster Extension Software Administrator Guide 81