HP 3PAR Cluster Extension Software Administrator Guide (5697-1429, March 2012)
A name, which can include alphabetic and numeric characters and underscores; for
example, an application startup value
string
A list of space-separated strings, for example, a list of host names (lists of numbers are
stored as lists of strings)
list
Text that is a comment starts with the pound (#) symbol and continues until the end of the line.
Comments can start on a new line or be part of a line specifying an object.
Specifying object values
You do not need to change the default settings unless you want to change the degree of protection
for your Remote Copy volume group members. If you change an object, you may need to change
additional objects as well. For example, if RESYNCWAIT has been specified for the
ApplicationStartup object, the ResyncWaitTimeout object must be specified.
Objects are supported according to the requirements or capabilities of the cluster software, as
indicated in Table 3 (page 61).
Table 3 Common and application objects
LinuxWindows ClusterCLIObject
••COMMON
••LogDir
•••LogLevel
•••APPLICATION
•••ApplicationDir
•••ApplicationStartup
•ClusterNotifyCheckTime
•ClusterNotifyWaitTime
•••DC_A_Hosts+
•••DC_B_Hosts+
•••DC_A_InServStorage_SerNum+
•••DC_B_InServStorage_SerNum+
•••RCVolumeGroupA+
•••RCVolumeGroupB+
•••PostExecCheck
•••PostExecScript
•••PreExecScript
•••ResyncWaitTimeout
•StatusRefreshInterval
•••UseNonCurrentDataOk
••HP3PARCLICommandTimeout
+ Required
• Supported
User configuration file 61