Users Guide - Platform Instrumentation Control
36
PIC Event Messages
PIC allows you to configure event actions to be taken on the managed server when an event occurs.
These actions include audio/visual notifications, such as:
• Display an alert message
• Write a message to the LCD
• Broadcast a message
The message text is based on the event information. This text contains the DMI MIF group and
attribute information that caused the error.
Alert Messages on the Server Console
The following table lists the alert messages that display on the server console. The general format
of these messages is:
Event reported for
<attribute_name> attribute in the <group_name> group.
Server Console Alert Messages
Alert Message Description
Event reported for Upper Critical Threshold
attribute in the Temperature Sensor group.
A temperature sensor on the system reported that the
current value is above the upper critical range.
Event reported for Upper Noncritical Threshold
attribute in the Temperature Sensor group.
A temperature sensor on the system reported that the
current value is above the upper noncritical range but
below the upper critical range. This message is also
generated when the temperature returns to the
acceptable range.
Event reported for Lower Noncritical Threshold
attribute in the Temperature Sensor group.
A temperature sensor on the system reported that the
current value is below the lower noncritical range but
above the lower critical range. This message is also
generated when the temperature returns to the
acceptable range.
Event reported for Lower Critical Threshold
attribute in the Temperature Sensor group.
A temperature sensor on the system reported that the
current value is below the lower critical range.
Event reported for Upper Critical Threshold
attribute in the Voltage Sensor group.
A voltage sensor on the system reported that the current
value is above the upper critical range.
Event reported for Upper Noncritical Threshold
attribute in the Voltage Sensor group.
A voltage sensor on the system reported that the current
value is above the upper noncritical range but below the
upper critical range. This message is also generated
when the voltage returns to the acceptable range.
Event reported for Lower Noncritical Threshold
attribute in the Voltage Sensor group.
A voltage sensor on the system reported that the current
value is below the lower noncritical range but above the
lower critical range. This message is also generated
when the voltage returns to the acceptable range.
continued