UserÆs Guide and Technical UserÆs Guide - HP Carrier Grade Server cc3300
HP cc3300 Carrier Grade Server Product Guide
34 Chassis Description
Power Supply in Alert Condition BLINK AMBER
Power supply failure (OTP, OCP, OVP, UV) AMBER
AC Input Voltage Specification
The power supply operates within all specified limits over the following input voltage ranges.
Harmonic distortion of up to 10% THD will not cause the power supply to exceed specified limits.
Table 12. AC Input Rating
Parameter MIN RATED MAX Max Input Current (350W Version)
Voltage (110) 90 V
rms
100-127 V
rms
140 V
rms
6.7 A
rms
Voltage (220) 180 V
rms
200-240 V
rms
264 V
rms
Frequency 47 Hz 63 Hz
DC Output Current Specifications
The combined output power of all outputs should not exceed 350 W. Each output has a maximum
and minimum current rating shown in Table 13. The power supply meets both static and dynamic
voltage regulation requirements for the minimum dynamic loading conditions. The power supply
meets only the static load voltage regulation requirements for the minimum static load conditions.
Table 13. 350W Load Ratings
+3.3V +5V +12V -12V 5VSB
PEAK (10sec) 30
A
MAX 20A 20A 25
A
0.5A 1.5A
MIN DYNAMIC 2.0A 2.0A 1.5
A
0
A
0A
MIN STATIC 1A 1A 0A 0A 0A
NOTE
The maximum combined power of the 3.3 V and 5 V outputs is 150 W.
Peripheral Bay
The peripheral bay consists of the following two removable media devices. Both devices are
replaced as one assembly.
• ½” Floppy drive
• ½” CD-ROM drive
Hard Drive Tray
The HP cc3300 Carrier Grade Server supports up to two internal disk drives. These disks may be of
different capacities and rotational speeds. An Ultra 160 SCSI controller contained on the system board as
part of core I/O provides the disk drives with an independent SCSI channel. This Ultra 160 SCSI controller
channel is independent of the Ultra 160 SCSI controller channel in core I/O that provides the external Ultra
160 SCSI port.