UserÆs Guide and Technical UserÆs Guide - HP Carrier Grade Server cc3300
HP cc3300 Carrier Grade Server Product Guide
14 Chassis Description
Environmental Specifications
The cc3300 Carrier Grade Server has been tested to the environmental specifications as indicated in
Table 2. All testing has been performed per procedures defined in Bellcore GR-63-CORE NEBS
Physical Protection, Bellcore GR-3580 NEBS Criteria Levels, Bellcore GR-1089-CORE EMC and
Electrical Safety – Generic Criteria for Network Telecommunications Equipment. .
Table 2. Environmental Specifications Summary
Environment Specification
Temperature operating
10 °C to 35 °C (50° F to 95° F)
Temperature non-operating
-40 °C to 70 °C (-104° F to 158° F)
Altitude 0 to 1,800 m (0 to 5,905 ft)
Humidity non-operating
95%, non-condensing at temperatures of 23° C (73° F) to 40° C (104° F)
Vibration operating Swept sine survey at an acceleration amplitude of 0.1 g from 5 to 100 Hz
and back to 5 Hz at a rate of 0.1 octave/minute, 90 minutes per axis on all
three axes as per Bellcore GR-63-CORE standards.
Vibration non-operating Swept sine survey at an acceleration amplitude of 0.5 g from 5 to 50 Hz at a
rate of 0.1 octaves/minute, and an acceleration amplitude of 3.0g from 50 to
500 Hz at a rate of 0.25 octaves/minute, on all three axes as per Bellcore
GR-63-CORE standard.
2.2 Grms, 10 minutes per axis on all three axes.
Shock operating Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes.
Shock non-operating Trapezoidal, 25 G, 170-inch/sec delta V, three drops in each direction, on
each of the three axes.
Electrostatic discharge
(ESD)
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to
8 kV contact discharge without physical damage.
Acoustic
Sound pressure: < 55 dBA at ambient temperatures < 28°C measured at
bystander positions in operating mode.
Sound power: < 6.5 BA at ambient temperatures < 28°C in operating mode.
Power
Maximum current at 100 VAC 1.8 Amps
Maximum current at 120 VAC 1.5 Amps
Maximum current at 230 VAC 0.8 Amps
Does the input current differ at 50 to 60Hz (if yes, input the highest value) No
Maximum peak inrush current 17.7 Amps
Time to decay to 25% of maximum peak 0.3 Seconds
Time duration to return to nominal 6 Seconds
Total harmonic distortion (voltage) 0.12%
Power factor 0.87
KVA rating 0.19 KVA
Heat dissipation 190 Watts
BTU’s per hour 649 BTU/hr