UserÆs Guide and Technical UserÆs Guide - HP Carrier Grade Server cc2300

cc2300 Carrier Grade Server Product Guide 47
Server Menu (continued)
Feature Option Description
Temperature Sensor [Disabled]
Enabled
If enabled, the system will not boot if the ambient
temperature is outside the range specified in
the SDR.
POST Error Pause [Enabled]
Disabled
If enabled, the system will wait for user intervention
on critical POST errors. If disabled, the system will
boot with no intervention, if possible.
Platform Event Filtering [Enabled]
Disabled
Enable/Disable trigger for system sensor events
inside the BMC.
System Management Submenu
Feature Option Description
Board Part Number [A46044-405] Field is informational only.
Board Serial Number [KKC212600176] Field is informational only.
System Part Number Field is informational only.
System Serial Number Field is informational only.
Chassis Part Number Field is informational only.
Chassis Serial Number Field is informational only.
BIOS Version Field is informational only.
BMC Revision Field is informational only.
HSBP Revision [ N/A ] Field is informational only.
Console Redirection Submenu
Feature Option Description
Serial Console Redirection [Disabled]
Enabled
Serial Port [COM1 3F8 IRQ4]
COM2 2F8 IRQ3
COM3 3E8 IRQ4
Baud Rate 9600
[19.2K]
38.4K
115.2K
Selects the serial port’s baud rate
Flow Control No Flow Control
[CTS/RTS]
XON / XOFF
CTS / RTS + CD
Hardware control
Software control
Hardware + Carrier Detect (for Modem use)