UserÆs Guide and Technical UserÆs Guide - HP Carrier Grade Server cc2300
cc2300 Carrier Grade Server Product Guide 15
KVA rating 0.16 KVA
Heat dissipation 160 Watts
BTU’s per hour 550 BTU/hr
Kcal per hour 38 Cal/sec
Nominal rated voltages 100 – 124 V
Maximum operating voltage 264 V
Minimum operating voltage 87 V
Rated (marked) line current(s) 3.0 Amps
Line voltage power-fail threshold 73 V
Dropout carry-through time at minimum line voltage 20 mSec
Mating AC input receptacle type C-13 C13, etc
Branch circuit breaker size at 100 VAC 15/20 Amps
Branch circuit breaker size at 120 VAC 15/20 Amps
Frequency range non-strappable 47 – 66 Hz
DC input (if applicable) 48 nominal Volts
DC input (if applicable) 3.2 Amps
EMC
ESD immunity – Maximum kV with no loss of function 4/8 kV
ESD immunity – Maximum kV with no component damage 4/8 kV
Sound power level (LWA) 6.6 B
Sound pressure level (LPA) at operator position 49.8 dB
Transient spike immunity amplitude 2 Kv
Transient spike immunity duration 50 Micro Sec
Transient spike immunity rise time 1.2 Micro Sec.