HP BladeSystem c7000 Enclosure Quick Setup Instructions
10
Connection Port number
Connects to
interconnect
bay/port
Comments
Mezzanine slot
2—1x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
5/Port N
6/Port N
7/Port N
8/Port N
Up to four
single-wide
interconnect
modules
Mezzanine slot
2—4x cards
4x port 1
4x port 2
5/Port N
7/Port N
One or two
double-wide
interconnect
modules
Mezzanine slot
3—1x or 2x
cards
1x/2x port 1
1x/2x port 2
1x/2x port 3
1x/2x port 4
7/Port N+8
8/Port N+8
5/Port N+8
6/Port N+8
Up to four
single-wide
interconnect
modules
Mezzanine slot
3—4x cards
4x port 1
4x port 2
5/Port N+8
7/Port N+8
One or two
double-wide
interconnect
modules
* Connectivity to interconnect bays 7 and 8 is only available with
four-port mezzanine cards or port 2 of 4x card in Mezzanine slot 2.
Mapping BL2x220c Blades
To support network connections for specific signals, install an
interconnect module in the bay corresponding to the embedded NIC or
mezzanine signals.
Interconnect device mapping for double dense server
blades
The following table lists the available configurations for double dense
server blades installed in device bay N (1-16).
Connection Port number
Connects to
interconnect bay/port
Server A
Embedded NIC
NIC 1 (ENET:1)
NIC 2 (ENET:2)
1/Port N
3/Port N
Server A
Mezzanine
Port 1
Port 2
5/Port N
6/Port N
Connection Port number
Connects to
interconnect bay/port
Server B
Embedded NIC
NIC 1 (ENET:1)
NIC 2 (ENET:2)
2/Port N
4/Port N
Server B
Mezzanine
Port 1
Port 2
7/Port N
8/Port N
Interconnect device mapping for AMC Telco I/O
expansion blades
The following table lists the available configurations for AMC Telco
I/O expansion blades installed in device bay N (1-16).
Connection Port number
Connects to
interconnect bay/port
AMC Embedded
(1)
Port 1
Port 2
Port 3
Port 4
1/Port N
2/Port N
3/Port N
4/Port N
AMC Embedded
(2)
Port 5
Port 6
Port 7
Port 8
5/Port N
6/Port N
7/Port N
8/Port N
Mapping the BL680c G7 Blade
• A side