HP BladeSystem PC Blade Switch Installation Guide

The following message is displayed.
Write Flash file name (Up to 8 characters, Enter for none.): config
File config (if present) will be erased after system initialization
======== Press Enter To Continue ========
4. Enter config as the name of the flash file.
The configuration is erased and the PC Blade Switch reboots.
5. Repeat the initial PC Blade Switch configuration.
Password Recovery [Option 3]
If a password is lost, you can perform the password recovery procedure from the Startup menu. The
password recovery procedure enables entry to the PC Blade Switch one time without a password.
To recover a lost password for the local terminal only:
From the Startup menu, type 3 and press Enter.
The password is deleted.
NOTE: To ensure security, reconfigure passwords for all applicable management methods.
Enter Diagnostic Mode [Option 4]
For Technical Support only.
Set Terminal Baud-Rate [Option 5]
To set the terminal baud-rate:
1. From the Startup menu, type 5 and press Enter.
2. Enter your choice or press Esc to exit.
3. Press Enter.
The baud-rate is set.
WARNING! If you change the terminal baud-rate, you must match these settings for the Integrated
Administrator's internal serial link to the PC Blade Switch. To do so, while logged into the PC Blade
Switch via the IA console, press Ctrl + Shift + _ then press C to Change Settings, then press R for
Remote Port [Switch A]. From there you can adjust the Baud Rate and Flow Control. Note: As the default
baud rate is set to 115200, there should be no reason to ever have to change these settings.
ENWW Startup Menu Procedures 27