Command Line Interface Reference Guide HP BladeSystem PC Blade Switch

HP PC Blade Switch CLI Reference Guide www.hp.com 20-13
RMON Commands
Last Sample Value The statistic value during the last sampling period. For example, if the
sample type is delta, this value is the difference between the samples at
the beginning and end of the period. If the sample type is absolute, this
value is the sampled value at the end of the period.
Interval The interval in seconds over which the data is sampled and compared with
the rising and falling thresholds.
Sample Type The method of sampling the variable and calculating the value compared
against the thresholds. If the value is absolute, the value of the variable is
compared directly with the thresholds at the end of the sampling interval. If
the value is delta, the value of the variable at the last sample is subtracted
from the current value, and the difference compared with the thresholds.
Startup Alarm The alarm that may be sent when this entry is first set. If the first sample is
greater than or equal to the rising threshold, and startup alarm is equal to
rising or rising and falling, then a single rising alarm is generated. If the
first sample is less than or equal to the falling threshold, and startup alarm is
equal falling or rising and falling, then a single falling alarm is generated.
Rising Threshold A sampled statistic threshold. When the current sampled value is greater
than or equal to this threshold, and the value at the last sampling interval is
less than this threshold, a single event is generated.
Falling Threshold A sampled statistic threshold. When the current sampled value is less than
or equal to this threshold, and the value at the last sampling interval is
greater than this threshold, a single event is generated.
Rising Event The event index used when a rising threshold is crossed.
Falling Event The event index used when a falling threshold is crossed.
Owner The entity that configured this entry.
Field Description