Brocade Network Advisor SAN User Manual v12.0.0 (53-1002696-01, April 2013)

Brocade Network Advisor SAN User Manual 897
53-1002696-01
SAN performance overview
29
SAN Performance measures
Performance measures enable you to select one or more measures to define the graph or report.
The measures available to you depend on the object type from which you want to gather
performance data.
NOTE
Devices with 10GE ports must be running Fabric OS 6.4.1ltd or later to obtain the correct TE port
statistics (TX/RX).
NOTE
Devices with 10GE ports must have the rmon MIB enabled on the switch. For more information
about the rmon collection command, refer to the Fabric OS Converged Enhanced Ethernet
Command Reference.
Current — Available in mAmps for installed SFPs.
Rx Power — Available in dBm for installed SFPs.
Tx Power — Available in dBm for installed SFPs.
Temperature — Available in Centigrade for installed SFPs.
Voltage — Available in mVolts for installed SFPs.
Tx % Utilization — available for FC, GE, Managed HBA ports, Managed CNA ports, E port trunks,
10GE ports, and FCIP tunnels.
Rx % Utilization — available for FC, GE, Managed HBA ports, Managed CNA ports, 10GE ports,
E port trunks, and FCIP tunnels.
Tx MB/Sec — available for FC, GE, Managed HBA ports, Managed CNA ports, 10GE ports,
E port trunks, FCIP tunnels, and End-to-End monitors.
Rx MB/Sec — available for FC, GE, Managed HBA ports, Managed CNA ports, 10GE ports,
E port trunks, FCIP tunnels, and End-to-End monitors.
CRC Errors — available for FC, Managed HBA ports, Managed CNA ports, 10GE ports and
End-to-End monitors.
Signal Losses — available for Managed HBA ports, Managed CNA ports, and FC ports.
Sync Losses — available for Managed HBA ports, Managed CNA ports, and FC ports.
Link Failures — available for Managed HBA ports, Managed CNA ports, and FC ports.
Sequence Errors — available for FC ports.
Invalid Transmissions — available for FC ports.
Rx Link Resets — available for FC ports.
Tx Link Resets — available for FC ports.
C3 Discard— available for FC ports.
C3 Discard RX Timeout— available for FC ports
C3 Discard Tx Timeout— available for FC ports
C3 Discard Unreachable— available for FC ports.
C3 Discard Others— available for FC ports.
Encode Error out— available for FC ports.
Dropped Packets — available for FCIP tunnels only.