.SAN design reference guide Vol. 1-5 785350-001
Figure 127 HP P9000 (XP) Continuous Access ESCON repeater configuration
Local
Remote
25326a
RCP
LCP
RCP
LCP
ESCON repeater/director
MME
MME
SME
MME
MME
SME
SME
SME
Table 161 HP P9000 (XP) Continuous Access ESCON director and repeater distances
Maximum distanceConfiguration
3 km for short-wave, multi-mode ESCON (MME)IBM 9032/9033 director
IBM 9036 repeater
20 km for long-wave, single-mode ESCON (SME)
Nbase Xyplex
43 km for director/repeater combination
Note: Supported only in a director-to-director
configuration.
Note: The ESCON protocol is not converted in this process.
WDM
Figure 128 (page 310) shows HP P9000 (XP) Continuous Access WDM (CWDM and DWDM)
configurations. Table 162 (page 310) describes the maximum supported distances and equipment.
Figure 128 HP P9000 (XP) Continuous Access WDM configurations
25328a
Local Remote
RCU
I
RCU
I
WDM
RCP
LCP
LCP
RCP
WDM
MME
MME
MME
MME
Table 162 HP P9000 (XP) Continuous Access WDM distances and equipment
Maximum distance and equipmentConfiguration
For supported distances, see Table 64 (page 156), Table 65 (page 156), and Table 68 (page
158).
Fibre Channel
Note: For Synchronous replication, distance impacts performance. HP recommends a maximum
distance of 200 km when using dark fiber.
HP P9000 (XP) Continuous Access is supported with all WDM products supported by the
switch vendors. See “Certified third-party WDM products” (page 317).
50 kmESCON
310 SAN extension