.SAN design reference guide Vol. 1-5 785350-001
Figure 87 SC GBIC transceiver
25143a
Table 131 (page 260) lists supported long-wave transceiver distances and maximum supported
distances under ideal operating conditions. Some long-wave optical transceivers can transmit up
to a distance of 100 km.
Table 131 Long-wave transceiver distances
Distance/rateTransceiverInterconnect speed
10 km ISL at 16 Gb/s (B-series)16 Gb/s 10 km SFP16 Gb/s
10 km ISL at 10 Gb/s (C-series)10 Gb/s 10 km SFP10 Gb/s
10 km ISL at 8 Gb/s (H-series with additional buffer credits
allocated)
1
8 Gb/s 10 km SFP
8 Gb/s
10 km ISL at 8 Gb/s (B-series and C-series)
3.3 km ISL at 8 Gb/s (H-series, base switch)
6.6 km ISL at 4 Gb/s (H-series, base switch)
10 km ISL at 2 Gb/s (H-series, base switch)
25 km ISL at 8 Gb/s (B-series)8 Gb/s 25 km SFP
10 km ISL at 4 Gb/s
4 Gb/s 10 km SFP
4 Gb/s
(B-series, C-series)
4 km ISL at 4 Gb/s
4 Gb/s 4 km SFP
(C-series)
30 km ISL at 4 Gb/s
4 Gb/s 30 km SFP
(extended-reach)
(B-series 8 Gb/s switches only)
35 km ISL at 2 Gb/s
2 Gb/s 35 km SFP
(extended-reach)
2 Gb/s
(B-series)
10 km ISL at 2 Gb/s
2 Gb/s 10 km SFP
(B-series, C-series)
10 km ISL at 1 Gb/s (B-series)1 Gb/s 10 km GBIC
1 Gb/s
10 km ISL at 1 Gb/s (C-series)1 Gb/s 10 km SFP
35 km ISL at 1 Gb/s (C-series )1 Gb/s 35 km SFP
100 km ISL at 1 Gb/s (B-series)1 Gb/s 100 km GBIC
1
You can use EFMS to allocate more buffer credits to ports of an H-series switch to achieve increased distance up to the limit of the
SFP capability.
260 SAN extension