.SAN design reference guide Vol. 1-5 785350-001

HP-UX SAN rules
This section describes the SAN rules for HP-UX.
For current storage system support, see the SPOCK website at http://www.hp.com/storage/spock.
You must sign up for an HP Passport to enable access.
Table 84 (page 191) describes the SAN configuration rules for HP-UX. Table 85 (page 192) describes
support for HP-UX storage, HBA, and multipathing coexistence.
Table 84 HP-UX SAN configuration rules
HP-UX SAN rules
Storage systems
1
All supported
Supports HP Serviceguard Clusters.
Zoning is required when HP-UX is used in a heterogeneous SAN with other operating systems.
Supports boot from SAN. See “P6000/EVA SAN boot support” (page 229) and “P9000/XP
SAN boot support” (page 238).
Supports connection to a common server for mixed storage system types. See “Common SAN
coexistence” (page 209).
Supports multipathing high-availability configuration in multiple fabrics or in a single fabric with
zoned paths. See “Data availability” (page 38).
P2000 G3 FC
Host name profile must be set to HP-UX
MSA2000fc G2
MSA2012 and MSA2212 FC are not supported with HP-UX
(MSA2300fc)
Support for HP-UX 11i v2 (June 2008 or later) using PvLinks
Support for HP-UX 11i v3 using native multipathing
EVA4100
Active/active failover mode is supported for HP-UX 11i v1 and 11i v2 using the Secure Path,
PvLinks, or Veritas DMP driver. HP-UX 11i v3 is supported with native multipathing.
NOTE: Secure Path support for HP-UX 11i v2 is not available on the P6XX0 arrays.
EVA4400
EVA6100
EVA6400
For HP P6000 Continuous Access configuration information, see “HP P6000 Continuous Access
SAN integration” (page 228).
EVA8100
EVA8400
P6300 EVA
P6350 EVA
P6500 EVA
P6550 EVA
SVSP
Host name profile must be set to HP-UX
Support for HP-UX 11iv2 using Secure Path (legacy only)
Support for HP-UX 11iv3 using native multipathing
SVSP 3.0
Host name profile must be set to HP-UX
Support for HP-UX 11iv3 using native multipathing
Zoning of host initiator ports, DPM target ports, DPM initiator ports, VSM ports and storage
target ports per SVSP requirements
3PAR StoreServ
10000/7000; 3PAR
F-Class, T-Class
Supported with HP-UX 11iv2 and 11iv3
Supports boot from SAN. See “3PAR SAN boot support” (page 254).
Zoning by HBA is required when used in a heterogeneous SAN, including other operating
systems and other storage system families or types.
All hosts must have the appropriate Host Operating System type parameter set (Host Persona)
and the required host settings described in the 3PAR HP-UX Implementation Guide.
HP-UX SAN rules 191