.SAN design reference guide Vol. 1-5 785350-001

disruption when a link fails between an NP_Port on the NPV devices and an F_Port on the external
fabric. To avoid disruption when an NP_Port goes online, the logins are not redistributed.
NPV mode considerations
Consider the following:
Nondisruptive upgrades are supported.
Grouping devices into different VSANs is supported.
A load-balancing algorithm automatically assigns end devices in a VSAN to one of the NPV
core switch links (in the same VSAN) at initial login.
You can connect B-series and C-series fabrics without interoperability constraints (for support
information, see the release notes).
A flexible licensing option is available (12 or 24 ports, with a 12-port upgrade option on the
12-port model).
You can select to use either switch mode or NPV mode.
Failover between NP_Ports (uplinks) is supported.
Direct storage attachment is not supported (requires at least one external Fibre Channel switch).
F_Ports, NP_Ports, and SD_Ports are supported.
NPIV-capable module servers (nested NPIV) are supported.
Local switching is not supported. All traffic is switched using the NPV core switch.
Remote SPAN is not supported.
NPV mode is managed separately from the BladeSystem; however, if used with C-series
switches, it uses a common SAN-OS.
NPV mode connectivity guidelines
NPV solutions are best suited for C-series-only fabrics in which you want multivendor switch
interoperability through NP_Ports instead of E_Ports. Figure 62 (page 174) shows an NPV device
with dual redundant fabrics.
Figure 62 NPV device with dual redundant fabrics
NP_Ports (NPIV) (uplinks)
Blade
enclosure
with
16 servers
Server Bay 1
Server Bay 2
Server Bay 3
Server Bay 4
Server Bay 5
Server Bay 6
Server Bay 7
Server Bay 8
Server Bay 9
Server Bay 10
Server Bay 11
Server Bay 12
Server Bay 13
Server Bay 14
Server Bay 15
Server Bay 16
N_Port Virtualization N_Port Virtualization
Blade
enclosure/
Server
management
SAN/
Storage
management
25346e
FC Fabric (B-series,
C-series, and H-series)
(with NPIV F_Port support)
FC Fabric (B-series,
C-series, and H-series)
(with NPIV F_Port support)
NOTE: The NP_Ports in Figure 62 (page 174) are not host N_Ports and cannot connect directly
to storage.
174 Heterogeneous server rules