.SAN design reference guide Vol. 1-5 785350-001
Table 56 H-series switch TR and remote B-series or C-series fabric rules (continued)
DescriptionRule number
you merge the two local fabrics, the transparent route becomes inactive for the devices that now have
a path over an ISL, and an alarm is generated.
IMPORTANT: SCM version 3.00 (or later) is required for the HP SN6000 Fibre Channel Switch.
SCM cannot manage or discover remote switches or devices in the remote fabric when using the
Transparent Router feature. The Physical Connection map displays the remote fabric as a disabled
switch, indicating that SCM cannot manage the switch.
Zoning limits and enforcement
Table 57 (page 149) lists zoning limits for H-series switches. See also “Zoning” (page 387).
Table 57 H-series switch zoning limits
Description
Rule
number
Maximum number of zone sets is 256.1
Maximum number of zones is 2,000.2
Maximum number of zones in a zone set is 2,000.3
Maximum number of zone members in a zone is 2,000.4
Maximum number of zone members per fabric is 10,000.5
Fabric rules 149