.Part 5 Storage Security Best Practices and Support Information HP SAN Design Reference Guide 785355-001
• Cable dressing
Use care when routing fiber optic cable and ensure that cables conform to the minimum bend
radius requirements. See “Rules for fiber optic cable connections ” (page 153). Use
hook-and-loop (such as Velcro brand) tie wraps to group and support the cables.
CAUTION: Plastic tie wraps can damage the internal fiber core if over-tightened.
• Cable symmetry
When connecting cables, use similar slot and port numbers. For example, connect HBA 1 to
SAN fabric 1, HBA 2 to SAN fabric 2, and so on.
Consider the following when configuring your SAN:
• “Fibre Channel switch configuration” (page 386)
• “Server setup” (page 386)
• “Storage system configuration” (page 386)
Fibre Channel switch configuration
HP Fibre Channel switches are preconfigured with compatible parameter settings. You must configure
each switch with a unique domain ID.
Server setup
When setting up servers:
• For each platform or operating system type, use only HP-supported drivers and configuration
settings.
• Ensure that the servers have the supported operating system versions and all required updates.
• Use an alphanumeric naming scheme for multiple servers of the same type, such as WIN01
and WIN02 for Windows servers.
Storage system configuration
When configuring storage systems:
• Use the storage map created in the planning phase to configure each storage system.
• Verify server-to-storage connectivity, and access one server at a time.
• When defining storagesets, disable all access first, and then enable the desired access.
• Define storage system connection names that are consistent with zoning alias names. Use
consistent names for storage port and controller connections. Use a naming scheme that
represents the physical connectivity.
Storage-based LUN masking
Use storage-based LUN masking to allow or prevent access to storage system LUNs from one or
more servers.
• For HP EVA storage systems, use SSP.
• For HP XP storage systems, use LUN Configuration and Security Manager XP.
During SCSI initialization, the server queries the storage port for a list of available LUNs and their
properties. The storage system compares the WWN of the requesting HBA to the defined zone
list and returns the LUNs assigned to the WWN. Any other LUNs on that storage port are not
available to the server.